Sign In | Join Free | My himfr.com
Home > Disinfectant Analyzer >

Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment from wholesalers
     
    Buy cheap Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment from wholesalers
    • Buy cheap Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment from wholesalers
    • Buy cheap Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment from wholesalers

    Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : WP10
    Certification : CE, ISO
    Price : Negotiable
    Payment Terms : T/T
    Delivery Time : 1-45 work days
    • Product Details
    • Company Profile

    Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

    Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment


    The two-electrode system membrane hydrogen peroxide sensor WP10 has the following features and advantages, making it an excellent performer in the field of water treatment:


    Features


    Mechanically strong membrane system

    The sensor adopts a high-strength membrane system design, which can operate stably in harsh environments and effectively prevent damage.


    Surfactant tolerance

    It has high tolerance to surfactants (such as detergents or chemical reagents) and is suitable for a variety of water quality conditions.


    High tolerance to chemicals

    It can resist the influence of a variety of chemicals (including strong oxidants or other corrosive substances) to ensure long-term stability.


    Applicable temperature range

    The working water temperature can reach up to 45℃, which meets most industrial water treatment needs.


    Multiple optional ranges

    Three ranges are available: 0200 ppm, 02000 ppm, and 0~20000 ppm, which meet different needs from trace detection to high concentration detection.


    Advantages


    Accurate measurement

    Using a two-electrode system, it has high sensitivity and accuracy and can quickly respond to changes in hydrogen peroxide concentration.
    Low maintenance requirements

    Durable design and stable operation reduce maintenance frequency and cost.


    Widely used

    Applicable to various water treatment processes, including drinking water, industrial wastewater, sewage and circulating cooling water.


    Easy to operate

    Modular design and user-friendly interface for easy installation and use.


    High stability

    Not affected by water flow fluctuations, capable of long-term continuous operation, reducing the risk of instrument drift and data errors.


    Two-electrode system, used in all water treatment, mechanically strong membrane system, resistant to surfactants, high resistance to chemicals, maximum water temperature: 45°C, optional range 0~200/2000/20000 ppm​



    Specifications


    WP10

    IndicatorHydrogen peroxide

    Application

    All kinds of water treatment, also sea water, especially for high H2O2- concentrations.

    The membrane system is mechanical resistant.

    The membrane system is highly resistant to surfactants (tensides).

    Measuring systemMembrane covered, amperometric 2-electrode system.

    Electronic

    Analog version: - voltage output

    - not galvanically isolated electronics

    - analog internal data processing

    - output signal: analog (analog-out/analog)

    Digital version: - electronic is completely galvanically isolated

    - digital internal data processing

    - output signal: analog (analog-out/digital)

    or

    digital (digital-out/digital)

    mA-version: - current output analog

    - not galvanically isolated electronics

    - output signal: analog (analog-out/analog)


    Information about the measuring range

    The actual slope of a sensor can vary production-related between 65% and 150% of the nominal slope

    Note: With a slope > 100% the measuring range is reduced accordingly.

    (Ex.: 150% slope → 67% of the specified measuring range)


    Working temperature

    Measuring water temperature: 0 … +45 °C

    (no ice crystals in the measuring water)

    Ambient temperature: 0 … +55 °C

    Temperature compensation

    Automatically, by an integrated temperature sensor Response time t90 = approx. 8 min.

    Max. change in temperature: 5 °C per hour, sudden temperature changes must be avoided


    Max. allowed working pressure

    Operation without retaining ring:

    - 0.5 bar

    - no pressure impulses and/or vibrations

    Operation with retaining ring in flow cell:

    - 1.0 bar,

    - no pressure impulses and/or vibrations

    (see option 1)

    Flow rate

    (Incoming flow velocity)

    Approx. 15-30 l/h (33 – 66 cm/s) in flow cell, small flow rate dependence is given
    pH-rangepH 2 – pH 11


    WP10

    Run-in timeFirst start-up approx. 5 h
    Response timeT90: approx. 8 min.

    Accuracy

    after calibration at repeatability conditions (25°C, pH 7.2 in drinking water) of the upper full scale

    - Measuring range 200 ppm: at 40 ppm <2%

    at 160 ppm <2%

    - Measuring range 2000 ppm: at 400 ppm <0,5%

    at 1600 ppm <2%

    Zero point adjustmentNot necessary
    calibrationAt the device, by analytical determination

    interferences

    Cl2: must not be present

    PAA: must not be present

    O3: must not be present

    Sulfides: contaminate the measuring system

    Phenol: aqueous solution >3 % phenol, destroys the membrane system

    Absence of the disinfectantMax. 24 h

    Connection

    mV version: 5-pole M12, plug-on flange

    Modbus version: 5-pole M12, plug-on flange

    4-20 mA version: 2-pole terminal

    or

    5-pole M12, plug-on flange

    Max. length of sensor cable (depending on internal signal processing)Analog< 30 m
    Digital

    > 30 m are permissible

    Maximum cable length depends on application

    Protection type

    5-pole M12 plug-on flange: IP68

    2-pole terminal with mA-hood: IP65

    MaterialElastomer membrane, PVC-U, stainless steel 1.4571

    Size

    Diameter: approx. 25 mm

    Length: mV version approx. 190 mm (analog signal processing)

    approx.. 205 mm (digital signal processing)

    Modbus version approx. 205 mm

    4-20 mA version approx. 220 mm (2-pole-terminal)

    approx. 190 mm (5-pole-M12)

    Transport+5 … +50 °C (Sensor, electrolyte, membrane cap)

    Storage

    Sensor: dry and without electrolyte no limit at +5 … +40 °C

    Electrolyte: in original bottle protected from sunlight at +5 … +35 °C min.

    1 year or until specified EXP-Date

    Membrane cap: in original packing no limit at +5 … +40 °C

    (used membrane caps can not be stored)



    WP10


    maintenance

    Regularly control of the measuring signal, min. once a week

    The following specifications highly depend on the water quality:

    Change of the membrane cap: once a year

    Change of the electrolyte: every 3 - 6 months



    Option 1: Retaining ring

    - When operating with pressures >0.5 bar in flow cell

    - Dimensions retaining ring 29 x 23.4 x 2.5 mm, slitted, PETP

    - Different positions for groove selectable (on request)



    Technical Data


    1. WP10 (Analog output, analog internal signal processing)

    A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation.


    Measuring rangeresolution

    Output

    Output resistance

    Nominal slopeVoltage supplyConnection
    WP10H-M120.5…200 ppm0.1 ppm

    0…-2000 mV


    1 kΩ

    -10 mV/ppm

    ±5 - ±15 VDC

    10 mA

    5-pole M12 plug-on flange


    Function of wires:

    PIN1: measuring signal PIN2: +U

    PIN3: -U

    PIN4: signal GND

    PIN5: n. c.

    WP10N-M125…2000 ppm1 ppm-1 mV/ppm
    WP10L-M120.005…2 % (20000 ppm)

    0.001 %

    (10 ppm)

    -1000mV/%

    (-0.1 mV/ppm)

    WP10-20%-M12

    0.05… 20%

    (200000 ppm)

    0.01 %

    (100 ppm)

    -100 mV/%

    (-0.01 mV/ppm)

    (Subject to technical changes!)

    2. WP10 (analog output, digital signal processing)

    Analog-out / digital

    The power supply is galvanically isolated inside of the sensor.

    The output signal is galvanically isolated too, that means potential-free.


    Measuring rangeResolutionOutput Output resistanceNominal SlopePower supplyConnection
    WP10H-An-M120.5… 200.0 ppm0.1 ppm


    analog
    0…-2 V (max.
    -2.5 V)
    1 kΩ

    -10 mV/ppm9-30 VDC
    approx.
    20-56 mA

    5-pole M12 plug-on flange


    Function of wires:

    PIN1: measuring signal PIN2: +U

    PIN3: power GND

    PIN4: signal GND

    PIN5: n. c.

    WP10N-An-M12.50… 2000 ppm1 ppm-1 mV/ppm
    WP10L-An-M120.005… 2 %
    (20000 ppm)
    0.001 %
    (10 ppm)
    -1000 mV/%
    (-0.1 mV/ppm)
    WP10-20%-An-M12

    0.05… 20 %

    (200000 ppm)

    0.01 %

    (100 ppm)

    -100 mV/%

    (-0.01 mV/ppm)

    WP10H-Ap-M120.5… 200.0 ppm0.1 ppm



    analog
    0…+2 V (max.
    +2.5 V)
    1 kΩ

    +10 mV/ppm
    WP10N-Ap-M125… 2000 ppm1 ppm+1 mV/ppm
    WP10L-Ap-M120.005… 2 %
    (20000 ppm)
    0.001 %
    (10 ppm)
    +1000 mV/%
    (+0.1 mV/ppm)
    WP10-20%-Ap-M120.05… 20 %
    (200000 ppm)
    0.01 %
    (100 ppm)
    +100 mV/%
    (+0.01 mV/ppm)

    (Subject to technical changes!)

    3. WP10 (digital output, digital signal processing)

    The power supply is galvanically isolated inside of the sensor.

    The output signal is galvanically isolated too, that means potential-free.



    Measuring rangeResolution

    Output

    Output resistance

    Power supplyConnection
    WP10H-M0c0.5… 200.0 ppm0.1 ppm

    Modbus RTU


    There are no terminating resistors in the sensor.


    9-30 VDC


    approx. 20-56 mA

    5-pole M12 plug-on flange


    Function of wires:

    PIN1: reserved

    PIN2: +U

    PIN3: power GND

    PIN4: RS485B

    PIN5: RS485A

    WP10N-M0c5… 2000 ppm1 ppm
    WP10L-M0c

    0.005… 2 %

    (20000 ppm)

    0.001 %

    (10 ppm)

    WP10-20%-M0c

    0.05… 20 %

    (200000 ppm)

    0.01 %

    (100 ppm)

    (Subject to technical changes!)

    4. WP10 4-20 mA (analog output, analog internal signal processing)

    A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation.

    4.1 Electrical connection: 2 pole terminal clamp


    Measuring rangeresolutionOutput Output resistanceNominal slopeVoltage supplyConnection
    WP10MA-2000.5… 200.0 ppm0.1 ppm

    4…20 mA

    uncalibrated
    0.08 mA/ppm

    12…30 VDC


    RL 50Ω…RL 900Ω

    2-pole terminal

    (2 x 1 mm²)


    Recommended: Round cable

    Æ 4 mm

    2 x 0.34 mm²

    WP10MA-20005… 2000 ppm1 ppm0.008 mA/ppm
    WP10MA-2%

    0.005… 2 %

    (20000 ppm)

    0.001 %

    (10 ppm)

    8 mA/%

    (0.0008 mA/ppm)

    WP10MA-5%

    0.05… 5 %

    (50000 ppm)

    0.01 %

    (100 ppm)

    3.2 mA/%

    (0.00032 mA/ppm)

    WP10MA-10%0.05… 10 %
    (100000 ppm)
    0.01 %
    (100 ppm)
    1.6 mA/%
    (0.00016 mA/ppm)
    WP10MA-20%0.05… 20 %
    (200000 ppm)
    0.01 %
    (100 ppm)
    0.8 mA/%
    (0.00008 mA/ppm)

    (Subject to technical changes!)


    4.2 Electrical connection: 5 pole M12 plug-on flange



    Measuring rangeresolutionOutput Output resistanceNominal slopeVoltage supplyConnection
    WP10MA-200-M120.5… 200.0 ppm0.1 ppm

    4…20 mA


    uncalibrated
    0.08 mA/ppm

    12…30 VDC


    RL 50Ω…RL 900Ω

    5-pole M12 plug-on flange


    Function of wires: PIN1: n. c.

    PIN2: +U

    PIN3: -U

    PIN4: n c.

    PIN5: n. c.

    WP10MA-2000-M125… 2000 ppm1 ppm0.008 mA/ppm
    WP10MA-2%-M12

    0.005… 2 %

    (20000 ppm)

    0.001 %

    (10 ppm)

    8 mA/%

    (0.0008 mA/ppm)

    WP10MA-5%-M12

    0.05… 5 %

    (50000 ppm)

    0.01 %

    (100 ppm)

    3.2 mA/%

    (0.00032 mA/ppm)

    WP10MA-10%-M120.05… 10 %
    (100000 ppm)
    0.01 %
    (100 ppm)
    1.6 mA/%
    (0.00016 mA/ppm)
    WP10MA-20%-M120.05… 20 %
    (200000 ppm)
    0.01 %
    (100 ppm)
    0.8 mA/%
    (0.00008 mA/ppm)

    (Subject to technical changes!)

    Spare Parts


    TypeMembrane capElectrolyteEmeryO-ring
    All WP10H

    M10.1H with G-holder Art. no. 11045.1

    EWP7/W, 100 ml

    Art. no. 11201

    S2

    Art. no. 11906

    20 x 1.5 silicone

    Art. no. 11803

    All WP10N
    All WP10L

    M10.1D with G-holder Art. no. 11041.1

    All WP10-20%
    All WP10MA-200

    M10.1H with G-holder Art. no. 11045.1

    All WP10MA-2000
    All WP10MA-2%

    M10.1D with G-holder Art. no. 11041.1

    All WP10MA-5%
    All WP10MA-10%
    All WP10MA-20%

    (Subject to technical changes!)


    Quality Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment for sale
    Inquiry Cart 0
    Send your message to this supplier
     