Sign In | Join Free | My himfr.com
Home > Disinfectant Analyzer >

Two-Wire 4-20mA Two-Electrode Ozone Sensor For Drinking Water, Direct Drinking Water, Service Process Water

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Two-Wire 4-20mA Two-Electrode Ozone Sensor For Drinking Water, Direct Drinking Water, Service Process Water from wholesalers
     
    Buy cheap Two-Wire 4-20mA Two-Electrode Ozone Sensor For Drinking Water, Direct Drinking Water, Service Process Water from wholesalers
    • Buy cheap Two-Wire 4-20mA Two-Electrode Ozone Sensor For Drinking Water, Direct Drinking Water, Service Process Water from wholesalers
    • Buy cheap Two-Wire 4-20mA Two-Electrode Ozone Sensor For Drinking Water, Direct Drinking Water, Service Process Water from wholesalers
    • Buy cheap Two-Wire 4-20mA Two-Electrode Ozone Sensor For Drinking Water, Direct Drinking Water, Service Process Water from wholesalers
    • Buy cheap Two-Wire 4-20mA Two-Electrode Ozone Sensor For Drinking Water, Direct Drinking Water, Service Process Water from wholesalers

    Two-Wire 4-20mA Two-Electrode Ozone Sensor For Drinking Water, Direct Drinking Water, Service Process Water

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : OZ1.2
    Certification : CE, ISO
    Price : Negotiable
    Payment Terms : T/T
    Delivery Time : 1-45 work days
    • Product Details
    • Company Profile

    Two-Wire 4-20mA Two-Electrode Ozone Sensor For Drinking Water, Direct Drinking Water, Service Process Water

    Two-Wire 4-20mA Two-Electrode Ozone Sensor For Drinking Water, Direct Drinking Water, Service Process Water


    Two-electrode system ozone sensor OZ1.2, used in drinking water, direct drinking water, service and process water, measuring water without surfactant, optional range 0~0.5/2/5/10/20ppm


    The functional characteristics of the ampere film ozone sensor include high sensitivity and fast response, which can accurately measure the ozone concentration in water. Its advantages are strong anti-interference ability, suitable for various water quality environments, and long service life. It is suitable for drinking water and industrial water treatment to ensure water quality safety.


    Specifications


    OZ1.2

    IndicatorOzone
    Application

    Swimming pool water, drinking water, service water, process water
    The water must not contain any surfactants (tensides)!

    Measuring systemMembrane covered, amperometric 2-electrode system

    Electronic

    Analog version: - voltage output

    - not galvanically isolated electronics

    - analog internal data processing

    - output signal: analog (analog-out/analog)

    Digital version: - electronic is completely galvanically isolated

    - digital internal data processing

    - output signal: analog (analog-out/digital)

    or

    digital (digital-out/digital)

    mA-version: - current output analog

    - not galvanically isolated electronics

    - output signal: analog (analog-out/analog)


    Information about the

    measuring range

    The actual slope of a sensor can vary production-related between 65% and 150% of the nominal slope

    Note: With a slope > 100% the measuring range is reduced accordingly.

    (Ex.: 150% slope → 67% of the specified measuring range)

    Slope drift

    At repeatability conditions

    (25 °C, pH 7,2 in drinking water)

    Approx. <- 1% per month

    Working temperature

    Measuring water temperature: 0 … +45 °C

    (no ice crystals in measuring water)

    Ambient temperature: 0 … +55 °C

    Temperature

    compensation

    Automatically, by an integrated temperature sensor
    Sudden temperature changes must be avoided


    Max. allowed working pressure

    Operation without retaining ring:

    - 0.5 bar

    - no pressure impulses and/or vibrations

    Operation with retaining ring in Flow cell:

    - 1.0 bar,

    - no pressure impulses and/or vibrations (see option 1)



    OZ1.2

    Flow rate

    (Incoming flow velocity)

    Approx. 15-30 l/h (33 – 66 cm/s) in flow FLC, small flow rate dependence is given
    pH-rangepH 1 – pH 11
    Run-in timeFirst start-up approx. 1 h
    Response timeT90 : approx. 15 sec.
    Zero point adjustmentNot necessary
    CalibrationAt the device, by analytical determination
    Interferences

    Cl2: factor 0.03
    ClO2: factor 0.7

    Absence of the disinfectantMax. 24 h

    Connection

    mV version:

    Modbus version:

    4-20 mA version:

    5-pole M12, plug-on flange

    5-pole M12, plug-on flange

    2-pole terminal

    or

    5-pole M12, plug-on flange

    max. length of sensor cable (depending on internal signal processing)analog< 30 m
    digital

    > 30 m are permissible

    Maximum cable length depends on application

    Protection type

    5-pole M12 plug-on flange: IP68

    2-pole terminal with mA-hood: IP65

    MaterialSemipermeable membrane, PVC-U, ABS

    Size

    Diameter:

    Length: mV version

    Modbus version 4-20 mA version

    approx. 25 mm

    approx. 190 mm (analog signal processing)

    approx.. 205 mm (digital signal processing)

    approx. 205 mm

    approx. 220 mm (2-pole-terminal)

    approx. 190 mm (5-pole-M12)

    Transport+5 … +50 °C (sensor, electrolyte, membrane cap)


    OZ1.2


    Storage

    Sensor: dry and without electrolyte no limit at +5 … +40 °C

    Electrolyte: in original bottle protected from sunlight at +5 … +35 °C min. 1

    year or until specified EXP-Date

    Membrane cap: in original packing no limit at +5 … +40 °C

    (used membrane caps can not be stored)


    Maintenance

    Regularly control of the measuring signal, min. once a week

    The following specifications depend on the water quality:

    Change of the membrane cap: once a year (depending on the water quality)

    Change of the electrolyte: every 3 - 6 months


    Option 1:

    Retaining ring


    - When operating with pressures >0.5 bar in flow cell

    - Dimensions retaining ring 29 x 23.4 x 2.5 mm, slitted, PETP

    - Different positions for groove selectable(on request)



    Technical Data

    1. OZ1.2 (analog output, analog internal signal processing)
    A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical
    isolation.

    Measuring range

    in ppm

    Resolution

    in ppm

    Output

    Output

    resistance

    Nominal

    slope

    in mV/ppm

    Voltage

    supply

    Connection
    OZ1.2H-M120.005…2.0000.001

    0…-2000 mV

    1 kΩ

    - 1000

    ±5 - ±15 VDC

    10 mA

    5-pole M12 plug-on flange


    Function of wires:

    PIN1: measuring signal

    PIN2: +U

    PIN3: -U

    PIN4: signal GND

    PIN5: n. c.

    OZ1.2N-M120.05…20.000.01- 100
    OZ1.2HUp-M120.005…2.0000.001

    0…+2000 mV

    1 kΩ

    +1000

    10 - 30 VDC

    10 mA

    5-pole M12 plug-on flange

    Function of wires:


    PIN1: measuring signal

    PIN2: +U

    PIN3: power GND

    PIN4: signal GND

    PIN5: n. c.

    OZ1.2NUp-M120.05…20.000.01+100

    (Subject to technical changes!)


    2. OZ1.2 (analog output, digital signal processing)
    Analog-out / digital
    -The power supply is galvanically isolated inside of the sensor.
    -The output signal is galvanically isolated too, that means potential-free.

    Measuring

    range

    in ppm

    Resolution

    in ppm

    Output

    Output resistance

    Nominal

    Slope

    in mV/ppm

    Power supplyConnection
    OZ1.2H-An-M120.005…2.0000.001

    analog

    0…-2 V

    (max. -2.5 V)

    1 kΩ

    - 1000

    9-30 VDC

    approx. 20-56 mA

    5-pole M12 plug-on

    flange


    Function of wires:

    PIN1: measuring signal

    PIN2: +U

    PIN3: power GND

    PIN4: signal GND

    PIN5: n. c.

    OZ1.2N-An-M120.05…20.000.01- 100
    OZ1.2H-Ap-M120.005…2.0000.001

    analog

    0…+2 V

    (max. +2.5 V)

    1 kΩ

    +1000
    OZ1.2N-Ap-M120.05…20.000.01+100

    (Subject to technical changes!)


    3. OZ1.2 (digital output, digital signal processing)
    -The power supply is galvanically isolated inside of the sensor.
    -The output signal is galvanically isolated too, that means potential-free.

    Measuring

    range

    in ppm

    Resolution

    in ppm

    Output

    Output resistance

    Power supplyConnection
    OZ1.2H-M0c0.005…2.0000.001

    Modbus RTU


    There are no terminating resistors in the sensor.

    9-30 VDC


    approx. 20-56 mA

    5-pole M12 plug-on flange

    Function of wires:

    PIN1: reserved

    PIN2: +U

    PIN3: power GND

    PIN4: RS485B

    PIN5: RS485A

    OZ1.2N-M0c0.05…20.000.01

    (Subject to technical changes!)


    4. OZ1.2 4-20 mA (analog output, analog internal signal processing)
    A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical
    isolation.
    4.1 Electrical connection: 2 pole terminal clamp

    Measuring

    range

    in ppm

    Resolutio n

    in ppm

    Output

    Output

    resistance

    Nominal

    slope

    in mA/ppm

    Voltage

    supply

    Connection
    OZ1.2MA0.50.005…0.5000.001

    4…20 mA

    uncalibrated

    32.0

    12…30 VDC

    RL 50Ω…RL 900Ω


    2-pole terminal

    (2 x 1 mm²)


    Recommended:

    Round cable

    4 mm

    2 x 0.34 mm²

    OZ1.2MA20.005…2.0000.0018.0
    OZ1.2MA50.05…5.000.013.2
    OZ1.2MA100.05…10.000.011.6
    OZ1.2MA200.05…20.000.010.8

    (Subject to technical changes!)

    4.2 Electrical connection: 5 pole M12 plug-on flange

    Measuring

    range

    in ppm

    Resolution

    in ppm

    Output

    Output

    resistance

    Nominal

    slope

    in mA/ppm

    Voltage

    supply

    Connection
    OZ1.2MA0.5-M120.005…0.5000.001

    4…20 mA

    uncalibrated

    32.0

    12…30 VDC

    RL 50Ω…RL 900Ω

    5-pole M12

    plug- on flange


    Function of wires:

    PIN1: n. c.

    PIN2: +U

    PIN3: -U

    PIN4: n c.

    PIN5: n. c.

    OZ1.2MA2-M120.005…2.0000.0018.0
    OZ1.2MA5-M120.05…5.000.013.2
    OZ1.2MA10-M120.05…10.000.011.6
    OZ1.2MA20-M120.05…20.000.010.8

    (Subject to technical changes!)


    Spare Parts

    TypeMembrane capElectrolyteEmeryO-ring
    For all OZ1.2

    M20.2
    Art. no. 11011.1

    EOZ1/W, 100 ml
    Art. no. 11101

    S1
    Art. no. 11908

    14 x 1.8 silicone
    Art. no. 11805

    (Subject to technical changes!)