Sign In | Join Free | My himfr.com
Home > Disinfectant Analyzer >

Two-Electrode System Chlorine Dioxide sensor For Drinking Water, Service And Process Water

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Two-Electrode System Chlorine Dioxide sensor For Drinking Water, Service And Process Water from wholesalers
     
    Buy cheap Two-Electrode System Chlorine Dioxide sensor For Drinking Water, Service And Process Water from wholesalers
    • Buy cheap Two-Electrode System Chlorine Dioxide sensor For Drinking Water, Service And Process Water from wholesalers
    • Buy cheap Two-Electrode System Chlorine Dioxide sensor For Drinking Water, Service And Process Water from wholesalers
    • Buy cheap Two-Electrode System Chlorine Dioxide sensor For Drinking Water, Service And Process Water from wholesalers
    • Buy cheap Two-Electrode System Chlorine Dioxide sensor For Drinking Water, Service And Process Water from wholesalers

    Two-Electrode System Chlorine Dioxide sensor For Drinking Water, Service And Process Water

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : CD4.2
    Certification : CE, ISO
    Price : Negotiable
    Payment Terms : T/T
    Delivery Time : 1-45 work days
    • Product Details
    • Company Profile

    Two-Electrode System Chlorine Dioxide sensor For Drinking Water, Service And Process Water

    Two-Electrode System Chlorine Dioxide sensor For Drinking Water, Service And Process Water


    Two-electrode system Chlorine Dioxide sensor CD4.2 Specially used to measure the concentration of chlorine dioxide in water. Used for drinking water, direct drinking water, service and process water, measuring water without surfactant, optional range 0~0.5/2/5/10/20ppm, its advantages and functional features include:
    High sensitivity: The amperometric method accurately measures the concentration of chlorine dioxide through electrochemical reactions and can detect lower concentrations of chlorine dioxide.
    Good selectivity: The sensor is specially designed for chlorine dioxide and has high selectivity, which can avoid interference from other oxidizing substances in the detection.
    Quick response: It can detect changes in chlorine dioxide in water in a short time and is suitable for real-time monitoring.
    Long-term stability: The use of coating technology can reduce electrode contamination, extend the service life of the sensor, and ensure long-term stable operation.
    Low maintenance cost: The coating design reduces direct contact with the electrode, reduces electrode wear and cleaning requirements, and reduces maintenance frequency.


    Functional features:
    Two-electrode design: It consists of a working electrode and a reference electrode, drives the electrochemical reaction through a potential difference, and measures the redox current of chlorine dioxide.

    Anti-pollution design: The coating acts as an isolation to protect the electrode from pollutants such as dirt and grease, and improves the performance of the sensor under complex water quality conditions.
    Real-time monitoring function: It is suitable for online water quality monitoring systems, can continuously measure chlorine dioxide concentration, and is suitable for automated control and monitoring in industrial processes.
    Temperature compensation function: Some sensors have temperature compensation function, which can ensure the accuracy of measurement at different temperatures.

    The ampere-coated two-electrode chlorine dioxide sensor can efficiently monitor the concentration of chlorine dioxide in water to ensure the safety and reliability of water quality.


    Scope of supply: CD4.2 sensor, membrane cap, electrolyte

    Specifications


    CD4.2

    IndicatorChlorine dioxide
    Application

    Swimming pool water, drinking water, service water, process water

    The water must not contain any surfactants (tensides)!

    Appropriate chlorine

    dioxide production

    methods

    e. g.

    - Acid/chlorite-method

    - Chlorine/chlorite-method

    Measuring systemMembrane covered, amperometric 2-electrode system with electronic inside

    Electronic

    Analog version: - voltage output

    - not galvanically isolated electronics

    - analog internal data processing

    - output signal: analog (analog-out/analog)

    Digital version: - electronic is completely galvanically isolated

    - digital internal data processing

    - output signal: analog (analog-out/digital)

    or

    digital (digital-out/digital)

    mA-version: - current output analog

    - not galvanically isolated electronics

    - output signal: analog (analog-out/analog)


    Information about the

    measuring range

    The actual slope of a sensor can vary production-related between 65% and 150% of the nominal slope

    Note: With a slope > 100% the measuring range is reduced accordingly.

    (Ex.: 150% slope → 67% of the specified measuring range)

    Slope drift

    At repeatability conditions

    (25 °C, pH 7,2 in drinking water)

    Approx. <- 1% per month

    Working temperature

    Measuring water temperature: 0 … +45 °C

    (no ice crystals in measuring water)

    Ambient temperature: 0 … +55 °C

    Temperature

    compensation

    Automatically, by an integrated temperature sensor

    Sudden temperature changes must be avoided


    Max. allowed working pressure

    Operation without retaining ring:

    - 0.5 bar

    - no pressure impulses and/or vibrations

    Operation with retaining ring in Flow cell:

    - 1.0 bar,

    - no pressure impulses and/or vibrations (see option 1)



    CD4.2

    Flow rate

    (Incoming flow velocity)

    Approx. 15-30L/h (33 – 66 cm/s) in flow cell, small flow rate dependence is given
    pH-rangepH 1 – pH 12 or the beginning of decomposition of chlorine dioxide at/over pH 12
    Run-in timeFirst start-up approx. 1 h
    Response timeT90 : approx. 15 sec.
    Zero point adjustmentNot necessary
    CalibrationAt the device, by analytical determination
    Interferences

    Cl2 : factor 0.35

    O3

    Absence of the

    disinfectant

    Max. 24 h

    Connection

    mV version:

    Modbus version:

    4-20 mA version:

    5-pole M12, plug-on flange

    5-pole M12, plug-on flange

    2-pole terminal

    or

    5-pole M12, plug-on flange

    Max. length of sensor cable

    (depending on internal

    signal processing)

    analog< 30 m
    digital

    > 30 m are permissible

    Maximum cable length depends on application

    Protection type

    5-pole M12 plug-on flange: IP68

    2-pole terminal with mA-hood: IP65

    MaterialSemipermeable membrane, PVC-U, ABS

    Size

    Diameter:

    Length: mV Version

    Modbus version 4-20 mA version

    approx. 25 mm

    approx. 190 mm (analog signal processing)

    approx.. 205 mm (digital signal processing)

    approx. 205 mm

    approx. 220 mm (2-pole-terminal)

    approx. 190 mm (5-pole-M12)

    Transport+5 … +50 °C (Sensor, electrolyte, membrane cap)


    CD4.2


    Storage

    Sensor: dry and without electrolyte no limit at +5 … +40 °C

    Electrolyte: in original bottle protected from sunlight at +5 … +35 °C min. 1

    year or until specified EXP-Date

    Membrane cap: in original packing no limit at +5 … +40 °C

    (used membrane caps can not be stored)


    Maintenance

    Regularly control of the measuring signal, min. once a week

    The following specifications depend on the water quality:

    Change of the membrane cap: once a year (depending on the water quality) Change of the electrolyte: every 3 - 6 months


    Option 1:

    Retaining ring


    - When operating with pressures >0.5 bar in flow cell

    - Dimensions retaining ring 29 x 23.4 x 2.5 mm, slitted, PETP

    - Different positions for groove selectable(on request)



    Technical Data

    1. CD4.2 (analog output, analog internal signal processing)

    A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation.

    Measuring

    range

    in ppm

    Resolution

    in ppm

    Output

    Output

    resistance

    Nominal

    slope

    in mV/ppm

    Voltage

    supply

    Connection

    CD4.2N-M12


    0.05…20.00


    0.01


    0…-2000 mV

    1 kΩ


    - 100

    ±5 - ±15 VDC

    10 mA

    5-pole M12 plug-on flange

    Function of wires:

    PIN1: measuring signal PIN2: +U

    PIN3: -U

    PIN4: signal GND

    PIN5: n. c.


    CD4.2H-M12


    0.005…2.000


    0.001


    - 1000

    (Subject to technical changes!)


    2. CD4.2 (analog output, digital internal signal processing)

    analog-out / digital

    - The power supply is galvanically isolated inside of the sensor.

    - The output signal is galvanically isolated too, that means potential-free.

    Measuring range


    in ppm

    Resolution


    in ppm

    Output

    Output resistance

    Nominal

    slope


    in mV/ppm

    Power supplyConnection
    CD4.2H-An-M120.005…2.0000.001

    analog

    0…-2 V (max. -2.5 V)

    1 kΩ

    - 1000

    9-30 VDC

    approx. 20-56 mA

    5-pole M12 plug-on flange

    Function of wires:

    PIN1: measuring signal PIN2: +U

    PIN3: power GND

    PIN4: signal GND

    PIN5: n. c.

    CD4.2N-An-M120.05…20.000.01- 100
    CD4.2H-Ap-M120.005…2.0000.001

    analog

    0…+2 V (max. +2.5 V)

    1 kΩ

    +1000
    CD4.2N-Ap-M120.05…20.000.01+100

    (Subject to technical changes!)


    3. CD4.2 (digital output, digital internal signal processing)

    - The power supply is galvanically isolated inside of the sensor.

    - The output signal is galvanically isolated too, that means potential-free.

    Measuring

    range

    in ppm

    Resolution

    in ppm

    Output

    Output resistance

    Power supplyConnection

    CD4.2H-M0c


    0.005… 2.000


    0.001

    Modbus RTU

    There are no terminating resistors in the sensor.

    9-30 VDC

    approx. 20-56 mA

    5-pole M12 plug-on flange

    Function of wires:

    PIN1: reserved

    PIN2: +U

    PIN3: power GND

    PIN4: RS485B

    PIN5: RS485A


    CD4.2N-M0c


    0.05… 20.00


    0.01

    (Subject to technical changes!)


    4. CD4.2 4-20 mA (analog output, analog internal signal processing)

    A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation.

    4.1 Electrical connection: 2 pole terminal clamp

    Measuring

    range

    in ppm

    Resolution

    in ppm

    Output

    Output

    resistance

    Nominal slope

    in mA/ppm

    Voltage supplyConnection
    CD4.2MA0.50.005…0.5000.001

    4…20 mA

    uncalibrated

    32.0

    12…30 VDC

    RL 50Ω…RL 900Ω


    2-pole terminal

    (2 x 1 mm²)


    Recommended:

    Round cable

    Two-Electrode System Chlorine Dioxide sensor For Drinking Water, Service And Process Water 4 mm

    2 x 0.34 mm²

    CD4.2MA20.005…2.0000.0018.0
    CD4.2MA50.05…5.000.013.2
    CD4.2MA100.05…10.000.011.6
    CD4.2MA200.05…20.000.010.8

    (Subject to technical changes!)


    4.2 Electrical connection: 5 pole M12 plug-on flange

    Measuring

    range

    in ppm

    Resolution

    in ppm

    Output

    Output

    resistance

    Nominal slope

    in mA/ppm

    Voltage supplyConnection
    CD4.2MA0.5-M120.005…0.5000.001

    4…20 mA

    uncalibrated

    32.0

    12…30 VDC

    RL 50Ω…RL 900Ω

    5-pole M12 plug-on flange

    Function of wires:

    PIN1: n. c.

    PIN2: +U

    PIN3: -U

    PIN4: n c.

    PIN5: n. c.

    CD4.2MA2-M120.005…2.0000.0018.0
    CD4.2MA5-M120.05…5.000.013.2
    CD4.2MA10-M120.05…10.000.011.6
    CD4.2MA20-M120.05…20.000.010.8

    (Subject to technical changes!)


    Spare Parts

    TypeMembrane capElectrolyteEmeryO-ring
    For all CD4.2

    M20.2

    Art. no. 11011.1

    ECD4 ● ECD7/W, 100 ml Art. no. 11030

    S1

    Art. no. 11908

    14 x 1.8 NBR

    Art. no. 11806

    (Subject to technical changes!)