Sign In | Join Free | My himfr.com
Home > Turbidity Analyzer >

MODBUS RS485 Circulation Digital Turbidity Analyzer For Wastewater Treatment

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap MODBUS RS485 Circulation Digital Turbidity Analyzer For Wastewater Treatment from wholesalers
     
    Buy cheap MODBUS RS485 Circulation Digital Turbidity Analyzer For Wastewater Treatment from wholesalers
    • Buy cheap MODBUS RS485 Circulation Digital Turbidity Analyzer For Wastewater Treatment from wholesalers
    • Buy cheap MODBUS RS485 Circulation Digital Turbidity Analyzer For Wastewater Treatment from wholesalers
    • Buy cheap MODBUS RS485 Circulation Digital Turbidity Analyzer For Wastewater Treatment from wholesalers
    • Buy cheap MODBUS RS485 Circulation Digital Turbidity Analyzer For Wastewater Treatment from wholesalers

    MODBUS RS485 Circulation Digital Turbidity Analyzer For Wastewater Treatment

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : DUC2-LTU-H-D
    Certification : CE
    Price : Negotiable
    • Product Details
    • Company Profile

    MODBUS RS485 Circulation Digital Turbidity Analyzer For Wastewater Treatment


    MODBUS RS485 Circulation Digital Turbidity Transmitter For Wastewater Treatment


    Brief Introduction


    Turbidity is one of the basic indicators of water quality monitoring, the turbidity value is high or low, intuitively reflecting the degree of turbidity of the water body. Turbidity is mainly caused by the insoluble substances in the water, insoluble substances including sediment suspended in the water, corrosive substances, planktonic algae, and colloidal particles.


    Turbidity is one of the indicators of the performance of drinking water clarity, it is also a reflection of the amount of microorganisms and organic matter content in drinking water-related indicators.


    A universal controller designed specifically for the DRFN digital series of turbidity sensors, compatible with all of DRFN's turbidity sensors.


    The connected sensors upload the detected data in a special encrypted communication method to ensure that the DUC controller can collect high-precision data in a more stable manner.


    The turbidity transmitter has 2 settable multi-function SPST relays and 2 high-precision 0/4~20mA current outputs. The operating temperature of the controller is 0~60℃, relative humidity less than 95%, no condensation.


    The protective grade of the DUC turbidity transmitter is IP66, which can effectively isolate the pollution of the external environment and the invasion of the corrosive gas. Rich output configurations are available to meet the different detection needs of many applications.


    Advantages Of The Turbidity Transmitter


    There are clock and historical data recording functions to meet higher data management requirements. The DUC turbidity analyzer can record 14000 historical data, record interval can be set between 1~999 minutes. The meter has power-off protection, parameters are retained indefinitely.


    The Menu password can be set to facilitate hierarchical management. Rich output to meet monitoring, control, and data remote transmission at the same time.


    The turbidity transmitter has a 3.2-inch display screen, using a 128*64 LCD screen, the backlight provides light and energy-saving mode to select. The language of it is Chinese or English.


    The DUC Universal Controller can accommodate a wide range of mounting options and can also be supplied with the necessary mounting accessories for installation.



    Applications Of The Turbidity Transmitter


    The turbidity transmitter is widely used in surface water, drinking water quality, municipal network water quality monitoring, industrial process water quality monitoring, wastewater treatment plant turbidity measurement, etc.


    Technical Parameters


    Product Name

    Turbidity transmitter

    Product Model

    DUC2-LTU-H-D

    Software Version

    DRFN TU Analysis software V1.0

    Turbidity Display Range

    0.001NTU~4000NTU

    Turbidity Resolution

    0.001NTU

    Relay Control

    2 settable SPST relays max. load 3A/250VAC

    Analog Current Output

    2 settable 0/4~20mA active current loop output max. load 1000Ω

    Communication Method

    MODBUS RTU; support JSON text data format

    Display Screen

    128*64 LCD, adjustable backlight mode

    Time History/Data Record

    Year/month/day/hour/min/second, record 14000 historical data

    Protection Level

    IP66

    Operating Environment

    0~60℃, relative humidity less than 95%

    Storage Environment

    -20~70℃, relative humidity less than 55%

    Shell Material

    Enhanced ABS

    Size

    144*144*120mm (hole size 138*138 mm)

    Mounting Method

    Wall mounting, pipe clamping, panel mounting

    Power Supply

    18~36V DC

    Weight

    800g

    Power Consumption

    12W
    Cleaning Systemmax. 24W (laser circulation sensor optional item)

    Quality MODBUS RS485 Circulation Digital Turbidity Analyzer For Wastewater Treatment for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Suzhou Delfino Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)