Sign In | Join Free | My himfr.com
Home > COD Analyzer >

UV254nm RS485 Chemical Oxygen Demand Analyzer Probe Modbus RTU

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap UV254nm RS485 Chemical Oxygen Demand Analyzer Probe Modbus RTU from wholesalers
     
    Buy cheap UV254nm RS485 Chemical Oxygen Demand Analyzer Probe Modbus RTU from wholesalers
    • Buy cheap UV254nm RS485 Chemical Oxygen Demand Analyzer Probe Modbus RTU from wholesalers
    • Buy cheap UV254nm RS485 Chemical Oxygen Demand Analyzer Probe Modbus RTU from wholesalers

    UV254nm RS485 Chemical Oxygen Demand Analyzer Probe Modbus RTU

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : CODuv351
    Certification : CE
    Price : Negotiable
    • Product Details
    • Company Profile

    UV254nm RS485 Chemical Oxygen Demand Analyzer Probe Modbus RTU


    Chemical Oxygen Demand Probe UV254nm COD Sensor With RS485 Modbus RTU


    The COD probe of Daruifuno adopts Spectral Absorption Coefficient (SAC) method, which can measure the absorption of light at a specific wavelength. The sensor doesn't need consumables during the measurement process. The COD electrode can measure COD, TOC, turbidity, temperature and other parameters. It uses two light sources, 254nm and 365nm UV reference light.


    Measuring Principle Of The COD Probe


    Many organic substances dissolved in water absorb ultraviolet rays, and the electromagnetic spectrum ranges from 200 to 390 nm. The simplest form of measurement using this principle is the Spectral Absorption Coefficient (SAC), which can measure the absorption of light at a specific wavelength. Traditionally, a wavelength of 254nm is used because it is located in an area sensitive to organic absorption.


    Therefore, by measuring the degree of absorption of ultraviolet light with a wavelength of 254 nm by organic substances, the substitution of organic substances in water can be detected.


    The chemical oxygen demand(COD) sensor can be used in a wide range of applications.


    Advantages Of The COD Probe

    • Automatically eliminate the interference of suspended solids and compensate for the interference of turbidity

    • Excellent test performance, achieve more stable and reliable measurement values

    • Integrated self-cleaning brush, small size and convenient to install, continuously monitor water quality online to prevent biological attachment and effectively reduce the frequency of maintenance.

    • Digital sensor, RS485 output, support MODBUS communication.

    • Drop-in installation, the tested sample does not need to be digested, the analysis speed is fast, no reagents need to be added, and there is no special sampling equipment.

    • The measurement process responds quickly in real-time without waiting.


    Applications Of The COD Probe


    • Monitoring for compliance
    • Optimization of wastewater treatment processes
    • Development of process control algorithms
    • Identification of cross-connected sewers
    • Identification of pollution sources
    • Rapid assessment of incident severity
    • Advanced treatment monitoring & protection
    • Effluent pollution

    Technical Parameters


    Product NameCOD probe
    Product ModelCODuv351
    Measuring PrincipleUV254 ultraviolet absorption method
    Measuring Range(COD)0.75~370mg/L
    Resolution(COD)0.01mg/L
    Accuracy(COD)±2% or ±2.5mg/L, take the larger one
    Measuring Range(TOC)0.3 ~150mg/L
    Accuracy(TOC)±2% or ±2.5mg/L, take the larger one
    Resolution(TOC)0.1mg/L
    Measuring Range(TU)0-300 NTU
    Accuracy(TU)3% or 0.2NTU, take the larger one
    Resolution(TU)0.1NTU
    Operating Temperature+5 ~ 45℃
    Calibration2-point calibration
    Protection GradeIP68
    Working Pressure1Bar
    Response TimeT90 max. 10s
    Flow Rate< 3 m/s
    Cleaning MethodRubber scraper
    Power12V 15mA (normal), 200mA (maximum, when cleaning)
    OutputRS485, Modbus RTU protocol
    DimensionDiameter 50mm, length 215mm
    Cable Length10m(custom)
    Shell MaterialPOM and 316L

    The Matched COD Controller Parameter


    Product NameCOD analyzer
    Product ModelDUC2-COD-H
    Software VersionDRFN COD analysis software V1.0
    Display Range0-1000 mg/L
    Resolution0.01 mg/L
    Relay Control2 settable SPST relays max. load 3A/250VAC
    Analog Current Output2 settable 0/4~20mA active current loop output max. load 1000Ω
    Communication MethodTwo-wire RS485 interface; MODBUS RTU; support JSON text data format
    Display Screen128*64 LCD
    Time History/Data RecordYear/month/day/hour/min/second, record 14000 historical data
    Protection LevelIP66
    Operating Environment0~60℃, relative humidity less than 95% (no condensation)
    Storage Environment-20~70℃, relative humidity less than 55% (no condensation)
    Shell MaterialEnhanced ABS
    Size144*144*120mm (hole size 138*138 mm)
    Mounting MethodWall mounting, pipe clamping, panel mounting
    Power Supply18 ~ 36V DC or 100~240V AC
    Weight800g
    Power Consumption12W

    Quality UV254nm RS485 Chemical Oxygen Demand Analyzer Probe Modbus RTU for sale