Sign In | Join Free | My himfr.com
Home > Chlorine Analyzer >

RS485 Chlorine Analyzers For Disinfectant Chlorine 24V

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap RS485 Chlorine Analyzers For Disinfectant Chlorine 24V from wholesalers
     
    Buy cheap RS485 Chlorine Analyzers For Disinfectant Chlorine 24V from wholesalers
    • Buy cheap RS485 Chlorine Analyzers For Disinfectant Chlorine 24V from wholesalers
    • Buy cheap RS485 Chlorine Analyzers For Disinfectant Chlorine 24V from wholesalers
    • Buy cheap RS485 Chlorine Analyzers For Disinfectant Chlorine 24V from wholesalers
    • Buy cheap RS485 Chlorine Analyzers For Disinfectant Chlorine 24V from wholesalers

    RS485 Chlorine Analyzers For Disinfectant Chlorine 24V

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : DUC2-CL-S-D
    Certification : CE
    Price : Negotiable
    • Product Details
    • Company Profile

    RS485 Chlorine Analyzers For Disinfectant Chlorine 24V


    RS485 Chlorine Transmitter For The Measurement Of Disinfectant Chlorine 24V


    Brief Introduction

    • Free chlorine is the most important disinfectant in water treatment due to its easy handling and strong disinfecting effect.

    • The DUC series disinfectant chlorine transmitter DUC2-CL-S-D used with the DRFN sensor helps to achieve safe and efficient disinfection by providing stable and fast measured values.

    • The CL controller is a digital universal controller for measuring the concentration of chlorine. Each controller will be pre-installed with a set of embedded software to adapt to different disinfectant sensors.

    • This digital chlorine analyzer is connected to the sensor. The sensor uploads the detected data in a special encrypted communication method. The DUC chlorine transmitter can collect high-precision data more stably. It is displayed on the display of the controller in real-time, which is very convenient for users to read.

    • The chlorine tester is equipped with a two-wire RS485 interface, the communication protocol is MODBUS RTU, and supports JSON text data format.

    • The instrument has 2 settable SPST multifunctional relays and 2 high-precision 0/4~20mA current outputs.


    Advantages Of The Chlorine Transmitter


    1. This disinfectant chlorine analyzer is equipped with RS485 Modbus RTU, RS485 Modbus RTU provides a stable and reliable communication solution suitable for industrial environments, enabling different types of equipment to communicate and control each other, which is beneficial to the integration and management of industrial automation systems.

    RS485 allows multiple devices to be connected to the same bus and perform data transmission and control through serial communication protocols, making the integration between devices simpler and more flexible.

    RS485 uses differential signal transmission, which can resist electromagnetic interference in industrial environments and ensure stable data transmission.

    RS485 can support relatively long communication distances, allowing devices to be distributed in distant locations while maintaining reliable communication.

    Modbus RTU is a widely used communication protocol. Its standardization allows devices from different manufacturers to communicate with each other, increasing the interoperability and compatibility of the devices.


    2. The DUC disinfectant chlorine transmitter has the functions of clock and historical data recording, which can meet the higher management requirements of users for data.


    3. 128*64 large-screen LCD display, Chinese and English language display, rich content, to meet the different needs of users.


    4. The shell material of the instrument is reinforced ABS, the shell is strong, corrosion-resistant, and wear-resistant. The overall size of the DUC chlorine gauge is 144*144*120mm, and the user can choose a variety of installation methods such as wall-mounted installation, pipe clamping installation, and panel installation.


    5. The controller has a power-off protection configuration, and the parameters can be kept indefinitely.


    Applications Of The Chlorine Transmitter


    It is applied to online monitoring of chlorine concentration in drinking water and industrial process water disinfection and sterilization process, sewage treatment and circulating cooling water treatment, and can also be used in swimming pools and other places where chlorine concentration needs to be measured.


    Technical Parameters


    Product Name

    Disinfectant Chlorine Transmitter

    Product Model

    DUC2-CL-S-D

    Software Version

    DRFN chlorine Analysis software V1.0

    Display Range

    0.01mg/L~100g/L

    Resolution

    0.01mg/L

    Relay Control

    2 settable SPST relays max. load 3A/250VAC

    Analog Current Output

    2 settable 0/4~20mA active current loop output max. load 1000Ω

    Communication Method

    Two-wire RS485 interface; MODBUS RTU; support JSON text data format

    Display Screen

    128*64 LCD

    Time History/Data Record

    Year/month/day/hour/min/second, record 14000 historical data

    Protection Level

    IP66

    Operating Environment

    0~60℃, relative humidity less than 95% (no condensation)

    Storage Environment

    -20~70℃, relative humidity less than 55% (no condensation)

    Shell Material

    Enhanced ABS

    Size

    144*144*120mm (hole size 138*138 mm)

    Mounting Method

    Wall mounting, pipe clamping, panel mounting

    Power Supply

    18-36V DC

    Weight

    800g

    Power Consumption

    7W


    The Matching DRFN Chlorine Sensors Recommendation


    • Model: CL4.2
    • pH range: 6~8

    • Pressure range: 0~1 bar, no pressure surges or fluctuations
    • Temperature range: 0~ 45℃ (no ice crystals in measurement water)
    • Integrated automatic temperature compensation
    • Response time: T90 about 30 seconds
    • Flow rate: about 30 l/h, low flow-dependence
    • Shaft length: standard 175 mm

    • Connection: Modbus RTU with M12 male
    • Material: PVC-U and semipermeable membrane
    • Applications: Fresh water free of surfactants and with constant pH


    Type:

    Measuring range:

    ppm

    Resolution:

    ppm

    Output signal:Power supply:Item number:
    CL4.2H-M0c0.005~2.0000.001Modbus RTU

    9~30 V DC

    20~56 mA

    3326225
    CL4.2N-M0c0.05~20.000.013326226
    CL4.2L-M0c0.5~200.00.13326227


    • Model: CC1
    • pH range: 4~12

    • Pressure range: 0~0.5 bar, no pressure surges or fluctuations
    • Temperature range: 0~ 45℃ (no ice crystals in measurement water)
    • Integrated automatic temperature compensation
    • Response time: T90 about 2min
    • Flow rate: about 30 l/h, low flow-dependence
    • Shaft length: standard 175 mm

    • Connection: Modbus RTU with M12 male
    • Material: PVC-U, PEEK, stainless steel 1.4571, microporous hydrophilic membrane
    • Applications: Fresh water and seawater; surfactants are tolerated in part; a special electrolyte is used for seawater


    Type:

    Measuring range:

    ppm

    Resolution:

    ppm

    Output signal:Power supply:Item number:
    CC1H-M0c0.005~2.0000.001Modbus RTU

    9~30 V DC

    20~56 mA

    3426610
    CC1N-M0c0.05~ 20.000.013426611


    • Model: CS4
    • pH range: 4~9

    • Pressure range: 0~3 bar, no pressure surges or fluctuations
    • Temperature range: 0~ 45℃ (no ice crystals in measurement water)
    • Integrated automatic temperature compensation
    • Response time: T90 about 2min
    • Flow rate: about 30 l/h, low flow-dependence
    • Shaft length: standard 175 mm

    • Connection: Modbus RTU with M12 male
    • Material: PVC-U, PEEK, stainless steel 1.4571, microporous hydrophilic membrane
    • Applications: Fresh water and sea water at 10 µS/cm~50 mS/cm, surfactants are partially tolerated


    Type:

    Measuring range:

    ppm

    Resolution:

    ppm

    Output signal:Power supply:Item number:
    CS4H-M0c0.005~2.0000.001ModBus RTU

    9~30 V DC

    20~56 mA

    3426360
    CS4N-M0c0.05~20.000.013426361
    CS4L-M0c0.5~200.00.13426362


    • Model: CP3
    • pH range: 4~12

    • Pressure range: 0~0.5 bar, no pressure surges or fluctuations
    • Temperature range: 0~ 45℃ (no ice crystals in measurement water)
    • Integrated automatic temperature compensation
    • Response time: T90 about 2min
    • Flow rate: about 30 l/h, low flow-dependence
    • Shaft length: standard 175 mm

    • Connection: Modbus RTU with M12 male
    • Material: PVC-U, PEEK, stainless steel 1.4571, microporous hydrophilic membrane
    • Applications: Swimming pool, drinking and seawater, surfactants are partially tolerated; special electrolyte for the use in sea water


    Type:

    Measuring range:

    ppm

    Resolution:

    ppm

    Output signal:Power supply:Item number:
    CP3H-M0c0.005~2.0000.001Modbus RTU

    9~30 V DC

    20~56 mA

    3326960
    CP3N-M0c0.05~20.000.013326961


    • Model: CN1.1
    • pH range: 6.5~9

    • Pressure range: 0~0.5 bar, no pressure surges or fluctuations
    • Temperature range: 0~ 45℃ (no ice crystals in measurement water)
    • Integrated automatic temperature compensation
    • Response time: T90 about 2min
    • Flow rate: about 30 l/h, low flow-dependence
    • Shaft length: standard 195 mm

    • Connection: Modbus RTU with M12 male
    • Material: PVC-U, PEEK, stainless steel 1.4571, microporous membrane
    • Applications: Check for the absence of chlorine in water


    Type:Measuring range: ppm

    Resolution:

    ppm

    Output signal:Power supply:Item number:
    CN1.1H-M0c0.005~2.0000.001Modbus RTU

    9~30 VDC

    20~56 mA

    3326610
    CN1.1H-M0c3326612



    • Model: AS2 AS3
    • pH range: 5~9

    • Pressure range: 0~8 bar, no pressure surges or fluctuations
    • Temperature range: 0~50℃(AS2), 0~70℃ (AS3)
    • Integrated automatic temperature compensation
    • Response time: T90 about 30s
    • Flow rate: about 30 l/h
    • Shaft length: standard 175 mm

    • Connection: Modbus RTU with M12 male
    • Material: PVC-U (AS2), PEEK (AS3)
    • Applications: Fresh water, especially drinking water, up to max. 70℃


    Type:

    (up to 50℃)

    Measuring range:

    ppm

    Resolution:

    ppm

    Output signal:Power supply:Item number:
    AS2H-CL-M0c0.005~2.000.001Modbus RTU

    9~30 V DC

    20~56 mA

    3426770
    AS2N-CL-M0c0.03~10.000.013426771

    Type:

    (up to 70℃)

    Measuring range:

    ppm

    Resolution:

    ppm

    Output signal:Power supply:Item number:
    AS3H-CL-M0c0.005~2.000.001Modbus RTU

    9~30 V DC

    20~56 mA

    3426720
    AS3N-CL-M0c0.03~10.000.013426721