Sign In | Join Free | My himfr.com
Home > Conductivity Analyzer >

RS485 Interface OTA Conductivity / TDS Analyzer For Pure Water

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap RS485 Interface OTA Conductivity / TDS Analyzer For Pure Water from wholesalers
     
    Buy cheap RS485 Interface OTA Conductivity / TDS Analyzer For Pure Water from wholesalers
    • Buy cheap RS485 Interface OTA Conductivity / TDS Analyzer For Pure Water from wholesalers
    • Buy cheap RS485 Interface OTA Conductivity / TDS Analyzer For Pure Water from wholesalers
    • Buy cheap RS485 Interface OTA Conductivity / TDS Analyzer For Pure Water from wholesalers
    • Buy cheap RS485 Interface OTA Conductivity / TDS Analyzer For Pure Water from wholesalers

    RS485 Interface OTA Conductivity / TDS Analyzer For Pure Water

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : DUC2-EC-S-A
    Certification : CE, ISO
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 10000 Sets per Month
    Delivery Time : 5-25 days
    • Product Details
    • Company Profile

    RS485 Interface OTA Conductivity / TDS Analyzer For Pure Water


    RS485 Interface OTA Conductivity /TDS analyzer For Pure Water


    DRFN conductivity controller can complete conductivity value and conductivity value measurement, temperature measurement, temperature compensation, current output, digital communication and other functions.


    The built-in clock chip can display the current time.


    The built-in memory chip of the instrument can save the past historical data, which is convenient for users to find.


    The instrument is equipped with a flushing relay function, and the electrode can be cleaned regularly by installing a solenoid valve.


    Specification:

    ModelDUC2-EC-S-A
    Software VersionDRFN EC Analysis software V1.0
    Sensor InputCompatible with all DRFN's EC Digital Sensors
    Display RangeConductivity0.000µS /cm ~500mS/cm
    Resistivity0.01Ω.cm~18MΩ.cm
    TDS0.000mg/L~500g/L
    Salinity(0.00~10.0)%
    Temp-10~500℃ /14~932℉
    ResolutionConductivity0.001µS /cm
    Resistivity0.01Ω.cm
    TDS0.001mg/L
    Salinity0.01%
    Temp0.1℃/ 0.1℉
    Relay Control2 settable SPST relays with a maximum load of 3A/250VAC
    Analog Current Output2 settable 0/4~20mA current outputs, max. load 1000Ω
    Communication Method

    Two-wire RS485 interface

    MODBUS RTU

    support JSON text data format

    OTA

    Default WIFI

    Display Screen128*64 LCD, adjustable backlight mode, adjustable display rate
    Configuration InformationPower off protection, parameters are retained indefinitely
    Time /Data Record

    Year/month/day/hour/min/second, record 14000 historical data

    record interval can be set between 1~999 minutes

    Maintenance RecordsLast 100 times
    Operating Environment0~60℃,RH<95% ( no condensation)
    Storage Environment-20~70℃,RH<55% ( no condensation, precision instruments)
    Shell MaterialEnhanced ABS
    Protection GradeIP66
    Dimension144*144*120 mm
    Mounting MethodWall mounting, pipe clamping, panel installation (hole size 138*138 mm)
    Electrical InterfaceThe back end reserved 3 M12*1.5 Gram head, line diameter 3~6.5 mm
    Power Supply

    100~240VAC

    Power ConsumptionAbout 7W
    WeightAbout 800g

    Please click the catalog of RS485 EC controller here:

    Daruifuno Catalog.pdf


    Brief introduction:
    ● Compatible with all DRFN conductivity sensors;
    ● Separately have a list of controller and sensor settings for quick and detailed parameter setting;
    ● The working status of the sensor can be queried, including reading the serial number;
    ● Support a variety of installation methods;
    ● Time and historical data recording function;
    ● 3.2-inch large LCD screen;
    ● User-friendly Chinese and English language interface;
    ● Password can be set to prevent misoperation;
    ● 2 SPST multi-function and settable relays;
    ● Two 0/4~20mA active current loop outputs;
    ● RS485 interface, Modbus RTU communication protocol;
    ● IP66 waterproof level, sealed enclosure can isolate pollution and corrosive gas;

    OTA download technology as a smart configuration option for the instrument.


    RS485 Interface OTA Conductivity / TDS Analyzer For Pure Water

    Aplication:
    ◇ Drinking water
    ◇ Pure water
    ◇ Cooling water
    ◇ Sewage
    ◇ Industrial process water


    FAQ


    Q1. Does the conductivity controller operation interface support customization?
    Yes, our conductivity controller
    operation interface can be tailored to customers' needs.


    Q2.Can customer's logo be added to the controller system and cover?
    Of course, we support OEM services for customers. Both the boot interface and the controller shell can be added to the customer's logo, but there is a minimum order quantity requirement.


    Q3.How long is the warranty period?
    The company guarantees the instrument for one year (12 months) from the date of shippment, and the consumables and wearing parts in the equipment are not covered by the warranty.


    Q4. Does the conductivity controller have an ambient temperature alarm function?
    Our EC controller has ambient temperature alarm function.


    Q5: What is your shipping method?
    A: Small orders are delivered by international express, Bulk orders are recommended to ship by sea.


    Q6: The conductivity controller with OTA function?

    Yes. Our DUC2-EC-S-D conductivity controller Default with OTA

    Quality RS485 Interface OTA Conductivity / TDS Analyzer For Pure Water for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Suzhou Delfino Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)