    Brand Name : Daruifuno
    Model Number : ASR301-VYD05
    Certification : CE
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 10000 Sets per Month
    Delivery Time : 5-25 days
    Price : Negotiable
    • Product Details
    • Company Profile

    ±2000mV 0 ~ 60℃ ABS ORP Sensor For Swimming Pool Water Monitoring

    ±2000mV 0~60℃ ABS ORP Sensor For Swimming Pool Water Monitoring


    Almost all ORP depends on chloride ion (Cl-) and pH (H+), just same as it depends on hypochlorous acid (chlorine in water).


    Any changes in chlorine concentration or pH value can affect ORP . Therefore, in order to measure chlorine accurately, chloride ion and pH value must be measured with high accuracy, or carefully controlled to constant values.


    ORP is not compensated for any change in temperature, and the vast majority of responses are pH-dependent.


    Specification:

    Product Name
    ORP sensor
    Model
    ASR301-VYD05
    ORP Range
    ±2000mV
    Reference Electrode
    Ag/AgCl
    Electrolyte
    Solid Gel
    Detection Heads
    Ring-shaped platinum
    Working Pressure
    0~2 Bar
    Working TEMP
    0~60℃
    Shaft Material
    ABS
    Membrane
    Porous Teflon membrane
    Thread Size

    1 inch NTP(both ends)


    Dimension
    D: 35mm L: 260 mm ( include cleaning cover)
    Lead Wire
    Standard 5m
    Temperature Unit
    ——
    Application
    Industrial water
    Cleaning

    A protective cover with its own cleaning interface(Optional)



    Please click the catalog of ORP controller here:

    Daruifuno Catalog.pdf


    Brief introduction:


    ◆ ORP composite electrode, the body adopts reinforced ABS plastic shell encapsulation


    ◆ The electrode is equipped with a protective cover with its own cleaning interface


    ◆ The electrode is divided into two basic types: ring platinum detection head and flat platinum detection head;


    ◆ Ring-shaped platinum has a wide response range and is suitable for sewage environment;


    ◆ Platinum is easier to clean and polish, suitable for water purification environment;


    ◆ The reference adopts a large-area annular porous Teflon diaphragm


    ◆ The reference system is designed with double salt bridge, the reference electrode is Ag/AgCl, filled with KCL solid gel.


    ±2000mV 0 ~ 60℃ ABS ORP Sensor For Swimming Pool Water Monitoring

    Aplication:

    Water treatment monitoring

    Drinking water,surface water,water quality analyze,ground water,ect.


    Industrial process monitoring and dosing control

    Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.


    FAQ

    1. Does ORP measurement require temperature compensation?

    A: ORP measurement is not temperature controlled, so the ORP sensor does not require temperature compensation.


    2. How do we choose the ORP electrode when the oxidation level is high?

    A: In occasions where the oxidation level is high, that is, the ORP value is high, platinum electrodes are recommended, otherwise gold electrodes are recommended. ORP measurements usually use the above two inert materials as indicator electrodes.


    3. What is the wire length of the ORP electrode?

    A: The lead wire of this electrode is 5m by default, other lengths need to be customized, contact our customer service, the price will vary with the change of length.


    4. What should ORP electrodes be used with?

    A: ORP electrode cannot be used alone, it must be connected with PH/ORP controller. We have a matching controller with a suitable price, and you can choose.


    5: Are you trading company or manufacturer ?

    A: We are a manufacturer, committed to producing high accuracy, long-term stability, cost-efficient online, portable(single-parameter and multi-parameter), water analysis instruments


    6: What's your quality control system?
    A: All of our products will be fully pre-inspection by QC departments before shipping to you . We have the certification of ISO,CE .


    7: What is your shipping method?
    A: Small orders are delivered with DHL, FedEx, TNT, UPS , EMS. Large orders are recommended to ship by sea.


    8: Do you provide samples ?
    A: Yes,we have materials in stock to help you to get the samples as soon as we can.


    9: Do you offer the OEM service?

    A: Yes, we can offer OEM service and design the logo marking for you. But the minimum quantity is 50pcs for the first order .

    Quality ±2000mV 0 ~ 60℃ ABS ORP Sensor For Swimming Pool Water Monitoring for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Suzhou Delfino Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)