Sign In | Join Free | My himfr.com
Home > pH ORP Sensor >

±2000mV 0 ~ 80℃ ORP Electrode With Platinum Head Glass For Swimming Pool

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap ±2000mV 0 ~ 80℃ ORP Electrode With Platinum Head Glass For Swimming Pool from wholesalers
     
    Buy cheap ±2000mV 0 ~ 80℃ ORP Electrode With Platinum Head Glass For Swimming Pool from wholesalers
    • Buy cheap ±2000mV 0 ~ 80℃ ORP Electrode With Platinum Head Glass For Swimming Pool from wholesalers
    • Buy cheap ±2000mV 0 ~ 80℃ ORP Electrode With Platinum Head Glass For Swimming Pool from wholesalers
    • Buy cheap ±2000mV 0 ~ 80℃ ORP Electrode With Platinum Head Glass For Swimming Pool from wholesalers

    ±2000mV 0 ~ 80℃ ORP Electrode With Platinum Head Glass For Swimming Pool

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : ASR201V-D05-A
    Certification : CE, ISO
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 10000 Sets per Month
    Delivery Time : 5-15 days
    • Product Details
    • Company Profile

    ±2000mV 0 ~ 80℃ ORP Electrode With Platinum Head Glass For Swimming Pool

    ±2000mV 0~80℃ ORP Electrode With Platinum Head Glass For Swimming Pool


    An ORP sensor consists of an ORP electrode and a reference electrode, just like a voltmeter measures the difference in potential (voltage). The principle of ORP measurement is to use an inert metal electrode (platinum, sometimes gold) which, due to its low resistance, will either give up electrons to the oxidizing agent (chlorine in this case) or accept electrons from the reducing agent (sulfur dioxide in the dechlorination process middle).


    The ORP electrode will continue to accept or give up electrons until it develops a potential, which is equal to the ORP of the solution due to the accumulation of charges. Typical ORP measurement accuracy is ±5 mV.


    Specification:

    Product Name
    ORP sensor
    Model
    ASR201V-D05-A
    ORP Range
    ±1500mV
    Reference Electrode
    Ag/AgCl
    Electrolyte
    Gel
    Detection Heads
    Ring-shaped platinum
    Working Pressure
    0~2 Bar
    Working TEMP
    0~80℃
    Shaft Material
    Glass
    Membrane
    Porous Teflon membrane
    Thread Size

    PG13.5


    Dimension
    D:12mm L:120mm
    Lead Wire
    Standard 5m
    Temperature Unit
    ——
    Application
    Dirty water
    Cleaning

    ——



    Please click the catalog of ORP controller here:

    Daruifuno Catalog.pdf


    Brief introduction:

    ◆ Glass shell ORP composite electrode, divided into two basic types: ring-shaped platinum detection head and flat platinum detection head;


    ◆ Ring-shaped platinum has a wide response range and is suitable for sewage environment;


    ◆ Platinum is easier to clean and polish, suitable for water purification environment


    ◆ The reference adopts annular porous Teflon diaphragm;


    ◆ The reference electrode is Ag/AgCl, and the reference is filled with KCL colorless high temperature gel;


    ◆ Porous Teflon membrane has the characteristics of fast penetration speed, fast response, not easy to block, and easy to clean;
    ◆ A mounting thread with a size of PG13.5 is provided at the end of the electrode, which is more convenient


    ±2000mV 0 ~ 80℃ ORP Electrode With Platinum Head Glass For Swimming Pool

    Aplication:

    Water treatment monitoring

    Drinking water,surface water,water quality analyze,ground water,ect.


    Industrial process monitoring and dosing control

    Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.


    FAQ

    1. Does ORP measurement require temperature compensation?

    A: ORP measurement is not temperature controlled, so the ORP sensor does not require temperature

    compensation.


    2. How do we choose the ORP electrode when the oxidation level is high?

    A: In occasions where the oxidation level is high, that is, the ORP value is high, platinum electrodes are recommended, otherwise gold electrodes are recommended. ORP measurements usually use the above two inert materials as indicator electrodes.


    3. What is the wire length of the ORP electrode?

    A: The lead wire of this electrode is 5m by default, other lengths need to be customized, contact our customer service, the price will vary with the change of length.


    4. What should ORP electrodes be used with?

    A: ORP electrode cannot be used alone, it must be connected with PH/ORP controller. We have a matching controller with a suitable price, and you can choose.


    5: Are you trading company or manufacturer ?

    A: We are a manufacturer, committed to producing high accuracy, long-term stability, cost-efficient online, portable(single-parameter and multi-parameter), water analysis instruments


    6: What's your quality control system?
    A: All of our products will be fully pre-inspection by QC departments before shipping to you . We have the certification of ISO,CE .


    7: What is your shipping method?
    A: Small orders are delivered with DHL, FedEx, TNT, UPS , EMS. Large orders are recommended to ship by sea.


    8: Do you provide samples ?
    A: Yes,we have materials in stock to help you to get the samples as soon as we can.


    9: How long will you give me the reply?
    A: We can support you 24Hours online service via email, skype, what’sapp, facebook etc within 1 hour.

    Quality ±2000mV 0 ~ 80℃ ORP Electrode With Platinum Head Glass For Swimming Pool for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Suzhou Delfino Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)