Sign In | Join Free | My himfr.com
Home > Conductivity Analyzer >

Analog OTA 0.00~200.00 MS/Cm Conductivity Transmitter For Waste Water

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Analog OTA 0.00~200.00 MS/Cm Conductivity Transmitter For Waste Water from wholesalers
     
    Buy cheap Analog OTA 0.00~200.00 MS/Cm Conductivity Transmitter For Waste Water from wholesalers
    • Buy cheap Analog OTA 0.00~200.00 MS/Cm Conductivity Transmitter For Waste Water from wholesalers
    • Buy cheap Analog OTA 0.00~200.00 MS/Cm Conductivity Transmitter For Waste Water from wholesalers
    • Buy cheap Analog OTA 0.00~200.00 MS/Cm Conductivity Transmitter For Waste Water from wholesalers
    • Buy cheap Analog OTA 0.00~200.00 MS/Cm Conductivity Transmitter For Waste Water from wholesalers
    • Buy cheap Analog OTA 0.00~200.00 MS/Cm Conductivity Transmitter For Waste Water from wholesalers

    Analog OTA 0.00~200.00 MS/Cm Conductivity Transmitter For Waste Water

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : AEC2-H3A
    Certification : CE, ISO
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 10000 Sets per Month
    Delivery Time : 5-25 days
    • Product Details
    • Company Profile

    Analog OTA 0.00~200.00 MS/Cm Conductivity Transmitter For Waste Water

    Analog OTA 0.00~200.00 MS/Cm Conductivity Transmitter For Waste Water

    The conductivity controller is a microprocessor-based control system that can operate in various water treatment applications. Specially designed for the blowdown and dosing controllers of cooling towers or boilers.

    Different applications require different water purity. For example, the conductivity of drinking water is usually less than 1 mS/cm. At the same time, the semiconductor and pharmaceutical industries require extremely pure water, which has a lower conductivity value than drinking water. The conductivity of pure water used for this application is generally less than 1 μS/cm. The conductivity can be measured with a two-electrode, four-electrode or ring (inductive) conductivity sensor. These conductivity measurements can be converted to TDS, salinity and concentration.

    Specification:

    ModelAEC2-H3A
    Software VersionDRFN EC Analysis software V1.0
    Display RangeEC

    0.00~200.00 mS/cm (Full range automatic switching)

    Resistivity0.01Ω.cm~18MΩ.cm
    TDS0.000mg/L~500g/L
    Salinity(0.00~10.0)%
    Display Range(Temp)-10~150℃ /14~302℉
    ResolutionEC0.01µS /cm
    Resistivity0.01Ω.cm
    TDS0.001mg/L
    Salinity0.1℃/ 0.1℉
    Accuracy0.1% of the measuring range
    Stability0.05% of the measuring range every 24 hours, no accumulation
    Repeatability0.1% better than the measuring range
    Temperature CompensationAutomatic or manual(NTC10K or PT1000)
    Relay OutputTwo SPST relays, maximum load 3A/250VAC
    CommunicationRS485 Modbus RTU
    Signal OutputTwo 0/4~20mA current outputs maximum load 1000Ω
    Sensor DiagnosisImage display
    Time history/data record

    Year/month/day/hour/min/second record 14000 historical data
    set interval between 1~999mins

    Maintenance records

    Last 100 times

    ConfigurationPower failure protection, indefinite retention of parameters
    LanguageChinese and English
    Display128*64 3.2-inch large graphic dot matrix LCD
    Protection GradeIP66
    Enclosure MaterialEnhanced ABS
    Power SupplyAC: 100~240V
    Dimension

    144*144*120mm

    Hole Size

    138*138mm

    Operating Temperature0~60℃, RH<95%, non-condensing
    Storage Temperature-20~70℃, RH<55%, non-condensing
    Installation Method

    Wall mount, pipe clamping, panel

    Weight800g
    Power Consumption5W

    Please click the user manual of conductivity controller here:

    Delfino Conductivity Controller Manual.pdf


    Brief introduction:

    ● 3.2-inch large LCD screen;
    ● User-friendly Chinese and English language interface;
    ● Password can be set to prevent misoperation;
    ● 2 SPST multi-function and settable relays;
    ● Two 0/4~20mA active current loop outputs;
    ● RS485 interface, Modbus RTU communication protocol;
    ● Temperature detection and compensation function;
    ● Shortcut button of AEC1 helps you perform daily maintenance quickly;
    ● IP66 waterproof level, sealed enclosure can isolate pollution and corrosive gas;
    ● Two dimensions, can meet a variety of installation methods, and provide the necessary installation accessories at the same time.

    Analog OTA 0.00~200.00 MS/Cm Conductivity Transmitter For Waste Water
    Aplication:
    ◇ Pure water ultra pure water
    ◇ drinking water
    ◇ Waste water
    ◇ Food and beverage industry

    ◇ chemical process
    ◇ Industrial water supply

    FAQ
    1. Which sensors can be connected to your EC controller?

    A: The EC meter can be compatible with DRFN EC sensors.

    2. The EC controller can provide resistivity, TDS, salinity and other related conductivity?
    The controller can also provide parameters such as resistivity, TDS, salinity and other related conductivity.































    Quality Analog OTA 0.00~200.00 MS/Cm Conductivity Transmitter For Waste Water for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Suzhou Delfino Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)