Sign In | Join Free | My himfr.com
Home > pH ORP Sensor >

Analog PH Electrode With PT1000 Temperature Compensation For Industrial Water

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Analog PH Electrode With PT1000 Temperature Compensation For Industrial Water from wholesalers
     
    Buy cheap Analog PH Electrode With PT1000 Temperature Compensation For Industrial Water from wholesalers
    • Buy cheap Analog PH Electrode With PT1000 Temperature Compensation For Industrial Water from wholesalers
    • Buy cheap Analog PH Electrode With PT1000 Temperature Compensation For Industrial Water from wholesalers
    • Buy cheap Analog PH Electrode With PT1000 Temperature Compensation For Industrial Water from wholesalers
    • Buy cheap Analog PH Electrode With PT1000 Temperature Compensation For Industrial Water from wholesalers

    Analog PH Electrode With PT1000 Temperature Compensation For Industrial Water

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : ASP300-TYD05
    Certification : CE
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 10000 Sets per Month
    Delivery Time : 5-15 days
    • Product Details
    • Company Profile

    Analog PH Electrode With PT1000 Temperature Compensation For Industrial Water


    Analog PH Electrode With PT1000 Temperature Compensation For Industrial Water


    pH measurement with a glass pH electrode relies on the measurement of a voltage.


    In order to measuring the voltage, two points with different electrical potential values are needed. The reference electrode is designed to maintain a constant electrical potential that is independent of the sample composition and temperature.


    In contrast, the hydrogen ion selective electrode (ISE) with glass membrane provides an electrical potential that is dependent upon the activity of hydrogen (H+) ions in the sample solution.


    Therefore, both the reference electrode and the hydrogen ISE are needed when determining pH.


    Specification:

    Modle

    ASP300-TYD05
    PH Range
    0~14pH 0.01pH
    Shaft Material
    ABS
    Working TEMP
    0~60℃
    Reference System
    double salt bridge
    Reference Electrode
    Ag/AgCl
    Electrolyte
    Solid Gel
    Working Pressure
    0~2Bar
    Operating Temperature
    0~60℃
    Working Pressure
    0~2Bar
    Temperature Unit
    Vacant/NTC10K /PT1000 (optional)
    Membrane
    Porous

    Glass Head


    Transparent low impedance


    Dimension
    Diameter: 35mm Length: 260 mm ( include the cleaning cover)
    Thread Size
    1 inch NTP(both ends)
    Lead Wire
    Standard 5m
    Ground
    --
    Cleaning
    A protective cover with its own cleaning interface(Optional)
    Application
    Industrial water

    Please click the pH sensor user manual here:

    PH sensor User Manual.pdf


    Brief introduction:

    ◆ pH composite electrode, the body adopts reinforced ABS plastic shell encapsulation, the structure is firm, there are installation threads at the beginning and the end, and the installation is convenient;


    ◆ The electrode is equipped with a protective cover with its own cleaning interface, and the user can quickly access the automatic cleaning system;


    ◆ The electrode is divided into 3 basic models according to the packaging method of the temperature unit;
    ◆ The indicator electrode adopts a low-impedance hemispherical glass head, which has high strength and is not easily broken;


    ◆ The reference adopts a large-area annular porous membrane, which has fast penetration speed, fast response, not easy to block, and easy to clean;


    ◆ The reference system is designed with double salt bridge, the reference electrode is Ag/AgCl, filled with KCL solid gel.


    ◆ Power supply mode: AC power supply 100~240VAC and DC power supply 18~36VDC.


    Analog PH Electrode With PT1000 Temperature Compensation For Industrial Water

    Aplication:

    Water treatment monitoring

    Drinking water,surface water,water quality analyze,ground water,ect.


    Industrial process monitoring and dosing control

    Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.


    FAQ

    1. What is themeasurement principle of this pH electrode?
    A: The pH value potentiometric method uses the potential difference of glass electrodes for pH measurement.


    2. How is this glass pH electrode composed?
    A:
    The pH electrode is usually composed of an indicator electrode and a reference electrode.


    3. How to judge the pH of the solution?
    A:
    If the internal hydrogen ion concentration of the pH glass bulb is lower than the outside, the measured solution is recorded as acidic and the pH value is lower than 7; if the two are the same, the solution is neutral and the pH value is equal to 7; if the internal hydrogen ion concentration is higher than externally, the measured solution is alkaline and the pH value is higher than 7.


    4. What is the wire length of the pH electrode?
    A:
    The lead wire of this electrode is 5m by default, other lengths need to be customized, contact our customer service, the price will vary with the change of length.


    5. How often must the pH sensor be calibrated?
    A: Depends on the type of sample: Dirty samples and non-aqueous samples require more frequent calibration. Depends on the required accuracy: For very accurate measurements, at least daily calibration is required. Depends on the quality of the electrode: Old electrodes require more frequent calibration.


    Quality Analog PH Electrode With PT1000 Temperature Compensation For Industrial Water for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Suzhou Delfino Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)