Sign In | Join Free | My himfr.com
Home > COD Analyzer >

UV254 Absorption RS485 COD / TOC / BOD Sensor For Industrial Process Monitoring

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap UV254 Absorption RS485 COD / TOC / BOD Sensor For Industrial Process Monitoring from wholesalers
     
    Buy cheap UV254 Absorption RS485 COD / TOC / BOD Sensor For Industrial Process Monitoring from wholesalers
    • Buy cheap UV254 Absorption RS485 COD / TOC / BOD Sensor For Industrial Process Monitoring from wholesalers
    • Buy cheap UV254 Absorption RS485 COD / TOC / BOD Sensor For Industrial Process Monitoring from wholesalers
    • Buy cheap UV254 Absorption RS485 COD / TOC / BOD Sensor For Industrial Process Monitoring from wholesalers
    • Buy cheap UV254 Absorption RS485 COD / TOC / BOD Sensor For Industrial Process Monitoring from wholesalers

    UV254 Absorption RS485 COD / TOC / BOD Sensor For Industrial Process Monitoring

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : COD351H
    Certification : CE
    Price : Negotiable
    • Product Details
    • Company Profile

    UV254 Absorption RS485 COD / TOC / BOD Sensor For Industrial Process Monitoring

    UV254 Absorption RS485 COD/TOC/BOD Sensor For Industrial Process Monitoring

    UV fluorescence absorption method COD sensor COD351H (Chemical Oxygen Demand) is a technique commonly used in water quality monitoring and analysis. They measure COD and TOC content based on the ultraviolet (UV) absorption and fluorescence properties of organic substances in the sample.

    Advantage technology:
    Rapid analysis: UV fluorescence absorption COD and TOC sensors can complete the analysis in a short time, saving time and effort compared with traditional chemical analysis methods.
    Real-time monitoring: These sensors can provide almost real-time monitoring results, allowing operators to understand water quality conditions in a timely manner and take necessary measures.
    Reagent-free: Traditional COD and TOC analysis requires the use of chemical reagents, while the UV fluorescence absorption sensor does not require reagents, thereby reducing environmental pollution and waste generation.
    High sensitivity: This technique is very sensitive to the measurement of organic substances and can detect low concentrations of COD and TOC.
    No pretreatment required: Compared with traditional methods, these sensors generally do not require complex sample pretreatment steps, making operation easier.
    Automation Integration: These sensors can be integrated with automation systems for remote monitoring and control.

    Technical Parameters

    ModelCOD351LCOD351H
    Measuring PrincipleUV254 Absorption Method
    Optical path6mm2mm
    Measuring Range

    COD: 0.75~500mg/L

    TOC: 0.3~200mg/L

    COD: 1~1500mg/L

    TOC: 0.4~600mg/L

    ResolutionCOD: 0.01mg/L TOC: 0.1mg/L
    Accuracy± 3% of the measurement + 0.5mg/L
    Related MeasurementTU: 0~300NTU accuracy: ± 5%TU: 0~1000NTU accuracy: ± 5%
    Response Time>1min
    Operating Tempe0~45℃ (does not freeze)
    Storage Temp-10~60℃
    Calibration MethodStandard solution
    Protection GradeIP68
    Working Pressure≤1bar
    Flow Ratenot depend on
    PowerDC 12V~24V
    CommunicationRS485, Modbus RTU protocol
    DimensionDiameter 60mm, length 215mm
    Lead InterfaceM16
    InstallationInvestment, 1 inch NPT pipe thread
    Shell MaterialPOM and 316L
    Power Consumption

    Normal measurement: 0.1W;

    Automatic cleaning by mechanical wiper: 3W;

    Abnormal jamming of mechanical wiper: 4.5W

    Weight720g


    Please click the user manual of Suspended Solids sensor here:


    Features

    • RS-485 output, support Modbus
    • No reagents, no pollution, environmentally friendly
    • Can measure COD, TOC, turbidity and temperature
    • Automatically compensate for turbidity interference
    • With self-cleaning brush and the maintenance cycle is longer

    Aplication:
    Water treatment plants: UV fluorescence absorption COD and TOC sensors are widely used in sewage treatment plants to monitor the content of organic substances in influent and effluent water to ensure that the discharge meets environmental protection standards.
    Environmental Monitoring: These sensors can be used for environmental monitoring such as monitoring of organic pollutants in rivers, lakes and ocean water bodies.
    Industrial process monitoring: In industrial production, especially those involving organic matter treatment, these sensors can be used to monitor water quality in real time to ensure stable production process and product quality.
    Food and beverage production: In the food and beverage industry, these sensors can be used to monitor water quality during production to ensure end product safety and compliance.
    Scientific research and laboratories: UV fluorescence absorption COD and TOC sensors are also widely used in scientific research and laboratories to analyze and study the organic content in different samples.

    Quality UV254 Absorption RS485 COD / TOC / BOD Sensor For Industrial Process Monitoring for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Suzhou Delfino Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)