Sign In | Join Free | My himfr.com
Home > Chlorophyll Analyzer >

Fluorescence Method RS485 Chlorophyll Sensor With Brush For Fresh Water

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Fluorescence Method RS485 Chlorophyll Sensor With Brush For Fresh Water from wholesalers
     
    Buy cheap Fluorescence Method RS485 Chlorophyll Sensor With Brush For Fresh Water from wholesalers
    • Buy cheap Fluorescence Method RS485 Chlorophyll Sensor With Brush For Fresh Water from wholesalers
    • Buy cheap Fluorescence Method RS485 Chlorophyll Sensor With Brush For Fresh Water from wholesalers
    • Buy cheap Fluorescence Method RS485 Chlorophyll Sensor With Brush For Fresh Water from wholesalers
    • Buy cheap Fluorescence Method RS485 Chlorophyll Sensor With Brush For Fresh Water from wholesalers
    • Buy cheap Fluorescence Method RS485 Chlorophyll Sensor With Brush For Fresh Water from wholesalers

    Fluorescence Method RS485 Chlorophyll Sensor With Brush For Fresh Water

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : CHL351
    Certification : CE, ISO9001
    Price :
    Supply Ability : 50 pieces per month
    Delivery Time : 20 days
    • Product Details
    • Company Profile

    Fluorescence Method RS485 Chlorophyll Sensor With Brush For Fresh Water


    Fluorescence Method RS485 Chlorophyll A Sensor With Brush For Fresh Water


    Fluorescent Chlorophyll A Sensor HL350/351 is a device that uses fluorescent signals to measure the content of chlorophyll A in water. Chlorophyll A is the main type of chlorophyll in plants and algae, and it plays a key role in the process of photosynthesis. Fluorescence sensors are based on the fluorescence characteristics of chlorophyll molecules, and determine the chlorophyll A content in water samples by measuring the fluorescence signals emitted by chlorophyll A molecules under light excitation.


    Technical Features:

    High sensitivity: It has high sensitivity and can detect extremely low concentrations of chlorophyll A. This makes it very effective in monitoring and analyzing changes in trace amounts of chlorophyll A in different water bodies.

    Non-destructive measurement: Fluorescence is a non-destructive measurement method that does not require destruction of the sample or addition of reagents. This means that it can be used during real-time or continuous monitoring without affecting the original state of the sample.

    Selectivity: Since the fluorescent chlorophyll A sensor is generated based on a specific fluorescent signal, it has high selectivity and can be distinguished from other colored substances, reducing interference.

    Fast measurement: Fluorescent Chlorophyll A sensors usually have a fast response time, making them suitable for applications that require fast monitoring, such as environmental monitoring, water quality assessment, etc.

    No need for expensive reagents: Compared to some other chemical analysis methods, the fluorogenic chlorophyll A sensor requires fewer reagents, thus reducing experimental costs.


    In general, the fluorescent chlorophyll A sensor technology plays an important role in the field of water environment monitoring and scientific research due to its high sensitivity, real-time monitoring ability and diverse application fields.


    Specification


    ModelCHL350CHL351
    Measuring TechnologyFluorescence method
    Measuring Range0~400ug/L or 0~100RFU
    Resolution0.1ug/L or 0.1% RFU
    Accuracy5% of the measuring range±0.5ug/L
    CommunicationRS485 MODBUS-RTU
    Response TimeT90≤30s
    Calibration Methodzero point and slope; Rhodamine calibration solution; Or compare calibration
    Work Pressure0~6Bar0~3Bar
    Sample Flow RateNot dependent
    Operating Temp0~50℃ (does not freeze)
    Storage Temp-10~60℃ (does not freeze)
    Shell MaterialTi+PPSTi
    DimensionDiameter: 22mm length: 180 mmDiameter: 37mm length: 200 mm
    Mounting ThreadM22*1.53/4NPT
    Lead interfaceM16 connector
    Protection GradeIP68
    Power Supply12~24V DC
    Power ConsumptionNormal measuring: 0.1W

    Normal measuring: 0.1W

    Automatic cleaning of wiper blades: 1W

    Wiper abnormal jamming: 3.5W

    Weight250g300g
    CableStandard 10 meters (other length can be customized)

    Advantages

    • Adopt optical principle, small size, convenient operation, fast detection speed
    • Excellent repeatability and stability, less susceptible to ambient light
    • With automatic cleaning brush can make maintenance intervals longer and prevent contamination and eliminate air bubbles.
    • No reagent consumption required, good stability, low maintenance effort
    • Internal storage of calibration data, support offline calibration, field plug and play
    • Standard Modbus communication protocol, support access to standard
    • The protection level is IP68, and the water quality dynamics can be controlled in real time.​​
    • Real-time monitoring: Fluorescent chlorophyll A sensors allow real-time monitoring of changes in chlorophyll A content in water bodies, which is very important for environmental monitoring, aquatic ecology research, and aquaculture and other fields.

    • Portability: The fluorescent chlorophyll A sensor is designed to be portable, and can be easily carried to the field or to different sampling points for on-site measurement, which is convenient for field application.

    • Automation and high-throughput: These sensors can be integrated with automated systems to enable high-throughput sample processing and analysis for increased efficiency.

    • Diverse applications: Fluorescent chlorophyll A sensors can not only be used for water quality monitoring, but also can be used in ecological research, marine science, biology and other fields to help researchers understand the dynamic changes of ecosystems.

    • Environmental friendliness: Fluorescent chlorophyll A sensors usually do not produce hazardous waste or chemical pollution during the measurement process, so they have advantages in terms of environmental protection.


    Applications

    Environmental monitoring: Fluorescent chlorophyll A sensors are widely used in environmental monitoring of water bodies, including fresh water, sea water, lakes, rivers, reservoirs, etc. By measuring the chlorophyll A content in the water body in real time or periodically, the nutritional status of the water body, the growth of algae and the change of water quality can be understood.

    Aquatic Ecology Research: These sensors play an important role in aquatic ecology research, helping scientists monitor and assess the health of aquatic ecosystems. By tracking changes in chlorophyll A content, we can understand the dynamics of algae growth in aquatic ecosystems and the impact of environmental changes on aquatic ecosystems.

    Aquaculture: In the aquaculture industry, controlling the chlorophyll A content in water is very important to maintain a healthy farming environment. The fluorescent chlorophyll A sensor can help farmers monitor the level of chlorophyll A in aquaculture ponds or water bodies, and take timely measures to prevent excessive eutrophication.

    Water source protection: Fluorescent chlorophyll A sensors can be used to monitor the water quality of water sources and help protect the safety of drinking water sources. By monitoring the chlorophyll A content, water pollution or eutrophication can be detected early.

    Scientific research: These sensors are also used in scientific research, including ecology, environmental science, hydrology and other fields. Fluorescent chlorophyll A sensors provide a fast and accurate measurement method that can provide researchers with rich data support.


    Fluorescent chlorophyll A sensors play an important role in various application environments related to water bodies, providing a powerful tool for environmental monitoring, scientific research and resource management.


    Quality Fluorescence Method RS485 Chlorophyll Sensor With Brush For Fresh Water for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Suzhou Delfino Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)