Sign In | Join Free | My himfr.com
Home > Dissolved Oxygen Analyzer >

Digital RS485 / SDI12 Communication Dissolved Oxygen Sensor Low Power Consumption

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Digital RS485 / SDI12 Communication Dissolved Oxygen Sensor Low Power Consumption from wholesalers
     
    Buy cheap Digital RS485 / SDI12 Communication Dissolved Oxygen Sensor Low Power Consumption from wholesalers
    • Buy cheap Digital RS485 / SDI12 Communication Dissolved Oxygen Sensor Low Power Consumption from wholesalers
    • Buy cheap Digital RS485 / SDI12 Communication Dissolved Oxygen Sensor Low Power Consumption from wholesalers
    • Buy cheap Digital RS485 / SDI12 Communication Dissolved Oxygen Sensor Low Power Consumption from wholesalers
    • Buy cheap Digital RS485 / SDI12 Communication Dissolved Oxygen Sensor Low Power Consumption from wholesalers
    • Buy cheap Digital RS485 / SDI12 Communication Dissolved Oxygen Sensor Low Power Consumption from wholesalers
    • Buy cheap Digital RS485 / SDI12 Communication Dissolved Oxygen Sensor Low Power Consumption from wholesalers

    Digital RS485 / SDI12 Communication Dissolved Oxygen Sensor Low Power Consumption

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : OPTOD
    Certification : CE
    Price : Negotiable
    Payment Terms : T/T
    Delivery Time : 1-45 work days
    • Product Details
    • Company Profile

    Digital RS485 / SDI12 Communication Dissolved Oxygen Sensor Low Power Consumption


    Low power consumption fluorescence digital RS485/SDI12 communication dissolved oxygen sensor


    The online dissolved oxygen sensor with low power consumption fluorescence method is a sensor that uses the principle of fluorescence method to measure dissolved oxygen, which has the advantages of low energy consumption and long-term monitoring.

    Low power consumption light source, sensitive layer and fluorescent material selection, low power consumption electronic circuit design, low power consumption microcontroller and communication module, energy saving mode and sleep mode, low power consumption fluorescence method online dissolved oxygen sensor can achieve long-term stable dissolution Oxygen monitoring and high efficiency in terms of energy consumption. It is suitable for applications requiring long-term and continuous monitoring of dissolved oxygen, such as environmental monitoring, water quality monitoring, water treatment and other fields.


    Advantages of The Optical Dissolved Oxygen Sensor

    • A low power consumption dissolved oxygen sensor
    • ASTM International Method D888-05 and Standard ISO 17289
    • Based on digital and lightweight designed sensor
    • Can be easily connected with online transmitters, DTU
    • RS485 Modbus protocol, support access to industrial control system
    • Protection grade IP68, can work continuously under water for a long time
    • Internal storage of calibration data, support offline calibration, plug and play

    Technical Characteristics


    ModelOPTOD-SOPTOD-TOPTOD-P
    Measuring TechnologyLuminescence optical measurement
    Measuring Range

    Saturation: 0~200%

    Dissolved oxygen: 0.00~20.00mg/L 0.00~20.00ppm

    Temp: 0~50℃

    ResolutionDissolved oxygen: 0.01mg/L Saturation: 1% Temp: 0.1℃
    AccuracyDissolved oxygen: ±0.1mg/L Saturation: ±1% Temp: ±0.1℃
    Response Time0~100% T90<40s, 100~0% T90<65s
    Water MoveNo necessary move
    Frequency of Measure>5s
    Digital OutputRS485, Modbus RTU and SDI-12
    Related CompensationTemp/salinity/pressure compensation
    CalibrationZero and span calibration
    Work Pressure0~5Bar
    Work Temperature0~50℃
    Storage Temp-10~60℃
    Material316L SSTiPOM
    Power SupplyDC 5~12V
    DimensionsDiameter: 25mm Length: 150mm

    Diameter 27mm, length 150mm

    Add protection head: length 170mm

    Lead interfaceIntegral
    ConnectionDefault barewires (9 armoured connectors, polyurethane jacket, waterproof Fisher connector need to be customized)
    Protection GradeIP68
    Installation InformationImmersed or piped installation (Requires mounting accessory support)
    CableStandard 7 meters (other length can be customized)
    Consumption

    Standby : 25 µA

    Average RS485 (1 measure/seconde) : 4.4 µA

    Average SDI12 (1 measure/seconde) : 7.3 mA

    Current pulse : 500 mA Heating time : 100 mA

    ApplicationSurface water, sewage, industrial effluent, urban wastewater

    Please click the pH sensor user manual here:

    OPTOD Sensor user manual.pdf


    Application Of The Optical Dissolved Oxygen Sensor

    Urban wastewater treatment
    Industrial effluent treatment
    Surface water monitoring
    Seawater
    Fish farming
    Aquarium

    Drinking water



    Common dissolved oxygen detection methods and their characteristics:


    1. Fluorescence sensor:
    Advantages: high sensitivity, wide measurement range, high accuracy, real-time monitoring, no sample processing, long life and stability.
    Disadvantages: special sensor equipment is required, and the cost is high.


    2. Electrochemical sensor (polarography or electrode method):
    Advantages: high sensitivity, real-time monitoring, no need for sample processing, and on-site measurement.
    Cons: Susceptible to interfering substances, requires regular calibration and maintenance.


    3. Oxygen concentration measuring instrument:
    Advantages: easy to use, real-time monitoring, no sample processing required.
    Disadvantages: narrow measurement range and low accuracy.


    4. Needle dissolved oxygen electrode:
    Advantages: real-time monitoring, no sample processing, and can be used in the field.
    Cons: Sensitive to temperature changes, requires regular calibration and maintenance.


    5. Dissolved oxygen measurement method in the bottle (wen bottle method):
    Advantages: relatively simple, suitable for laboratory conditions.
    Disadvantages: Not suitable for real-time monitoring, requires sample sampling, susceptible to external interference.


    Quality Digital RS485 / SDI12 Communication Dissolved Oxygen Sensor Low Power Consumption for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Suzhou Delfino Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)