Sign In | Join Free | My himfr.com
Home > pH ORP Controller >

0~14pH 4~20mA or 0~20mA Online pH ORP Meter Controller For Water Treatment

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 0~14pH 4~20mA or 0~20mA Online pH ORP Meter Controller For Water Treatment from wholesalers
     
    Buy cheap 0~14pH 4~20mA or 0~20mA Online pH ORP Meter Controller For Water Treatment from wholesalers
    • Buy cheap 0~14pH 4~20mA or 0~20mA Online pH ORP Meter Controller For Water Treatment from wholesalers
    • Buy cheap 0~14pH 4~20mA or 0~20mA Online pH ORP Meter Controller For Water Treatment from wholesalers
    • Buy cheap 0~14pH 4~20mA or 0~20mA Online pH ORP Meter Controller For Water Treatment from wholesalers
    • Buy cheap 0~14pH 4~20mA or 0~20mA Online pH ORP Meter Controller For Water Treatment from wholesalers
    • Buy cheap 0~14pH 4~20mA or 0~20mA Online pH ORP Meter Controller For Water Treatment from wholesalers

    0~14pH 4~20mA or 0~20mA Online pH ORP Meter Controller For Water Treatment

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : APX2-C1
    Certification : CE
    Price : Negotiable
    Payment Terms : D/A, L/C, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 100 Unit/Week
    Delivery Time : 7-10 work days
    • Product Details
    • Company Profile

    0~14pH 4~20mA or 0~20mA Online pH ORP Meter Controller For Water Treatment


    0~14pH 4~20mA or 0~20mA Online pH ORP Meter Controller For Water Treatment


    ‍pH/ORP controller (also known as pH meter) equipment is suitable for the control of PH and ORP values in electroplating, metallurgy, textile, chemical and other wastewater, giving new life to the traditional chemical treatment method, fully realizing automatic monitoring, automatic medication, to ensure that the discharge of wastewater to meet the national discharge standards.


    Advantages of pH/ORP controller:

    • pH glass electrode measurement method
    • Two configurable SPST multifunction relays
    • With 1 high-precision 0/4-20mA current output
    • 3.2 inch LCD screen, rich content
    • Support multiple installation methods
    • AC and DC power modes, both wide voltage
    • Housing material reinforced ABS, protection class IP66


    pH ORP controller Parameters:

    Display RangepH: 0~14pH
    ORP: -2000mV~2000mV
    Temp.:-10~+150℃
    ResolutionpH: 0.01pH ORP: 1mV Temp.: 0.1℃
    Accuracy±0.02pH/±2mV
    Temp. CompensationNTC10K/PT1000 automatic or manual
    Relay ControlChannel Quantity: 2
    Control Type: main value control/temp. control/wash control
    Contact Type: SPST
    Contact Capacity: 3A 250V AC
    Current OutputChannel Quantity: 1
    Output Type: active 4~20mA or 0~20mA
    Max. Load: 1000Ω
    Display Screen3.2 inch graphic LCD display
    Configuration informationPower failure protection, parameters are retained indefinitely
    Operating Environment0~+60℃, relative humidity 0~95%, no condensation
    Storage Environment-20~+70℃, relative humidity 0~55%, no condensation
    Power Supply100~240VAC or 18~36VDC, 3W Max
    Installation MethodPanel / wall / pipe mounting
    Instrument Dimension144*144*120 (unit: mm)
    Protection GradeIP66
    Instrument WeightAbout 800g


    Probe Setting
    Perform sensor calibration and view of sensor status.
    After the probe is connected to the controller, it needs to be calibrated first due to the error between
    the signal of the actual electrode and the standard.
    pH Calibration
    1. Preparation before calibration
    • In the menu “ select probe ”, select “ pH Glass probe ” or “ pH Antimony probe ”
    • pH 4.01, 6.86, 9.18 standard solution (1)
    • Deionized cleaning solution and absorbent paper
    2. Zero Calibration
    (1) Clean the probe with deionized cleaning solution, dry it with absorbent paper and put it
    into pH 6.86 standard solution;
    (2) After the measured value is stable, select “ 6.86pH CAL ” to start calibration;
    3. Acid slope Calibration
    (1) Clean the probe with deionized cleaning solution, dry it with absorbent paper and put it
    into pH 4.01 standard solution;
    (2) After the measured value is stable, select “ 4.01pH CAL ” to start calibration;
    4. Alkali slope Calibration
    (1) Clean the probe with deionized cleaning solution, dry it with absorbent paper and put it
    into pH 9.18 standard solution;
    (2) After the measured value is stable, select “ 9.18pH CAL ” to start calibration;
    ORP Calibration
    1. Preparation before calibration
    • In the menu “ select probe ”, select “ ORP probe ”
    • ORP 86mV, 256mV standard solution (1)
    • Deionized cleaning solution and absorbent paper
    2. Zero Calibration
    (1) Clean the probe with deionized cleaning solution, dry it with absorbent paper and put it
    into ORP 86mV standard solution ;
    (2) After the measured value is stable, select " 86mV CAL " to start calibration;
    3. Slope Calibration
    (1) Clean the probe with deionized cleaning solution, dry it with absorbent paper and put it
    into ORP 256mV standard solution;
    (2) After the measured value is stable, select " 256mV CAL " to start calibration;


    pH ORP controller Applications:

    Water treatment monitoring: drinking water, surface water source water quality, groundwater, environmental sewage discharge monitoring, urban drainage network monitoring
    Industrial process monitoring: chemical industry, petroleum, paper making, food and medicine, PCB electroplating, etc


    If you are interested in more product information about pH ORP controller APX2-C1, please contact us.




    Quality 0~14pH 4~20mA or 0~20mA Online pH ORP Meter Controller For Water Treatment for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Suzhou Delfino Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)