Sign In | Join Free | My himfr.com
Home > Chlorine Analyzer >

4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water from wholesalers
     
    Buy cheap 4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water from wholesalers
    • Buy cheap 4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water from wholesalers
    • Buy cheap 4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water from wholesalers
    • Buy cheap 4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water from wholesalers
    • Buy cheap 4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water from wholesalers
    • Buy cheap 4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water from wholesalers
    • Buy cheap 4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water from wholesalers

    4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : CL4.2
    Certification : CE
    Price : Negotiable
    • Product Details
    • Company Profile

    4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water

    4-20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water


    Amperometric Membrane Method (Amperometric Membrane Method) residual chlorine sensor CL4.2 is a sensor technology commonly used to measure the concentration of residual chlorine in water. It is based on the principle of electrochemistry, by measuring the current to determine the content of residual chlorine in the water sample.


    Advantage:
    High sensitivity: The film-attached residual chlorine sensor has high sensitivity and can perform accurate measurement in the range of low residual chlorine concentration, which is very important for applications that require strict monitoring of water quality.

    Real-time monitoring: This sensor can provide real-time residual chlorine concentration data, allowing users to quickly understand changes in water quality and take necessary measures to maintain water quality safety.

    Quick response: The film-attached sensor has a fast response speed, and can quickly detect changes in residual chlorine, so that measures can be taken in time to protect water quality.

    Stability: These sensors typically have good long-term stability and repeatability, providing accurate and reliable measurements over long periods of time.

    Automation integration: The film-attached residual chlorine sensor can be equipped with RS485 and integrated with the automation system to realize automatic monitoring and alarm, thereby reducing the need for manual operation and intervention.


    With its high sensitivity, real-time monitoring capability and stability, the film-attached residual chlorine sensor CL4.2 is mainly used in the design of drinking water environment.


    Specifications

    IndicatorFree chlorine
    pH Range6~8pH
    Pressure Range0~1 bar, no pressure surges or fluctuations
    Temperature Range0~45℃
    Temp CompensationIntegrated automatic temperature compensation
    Response TimeT90 30 seconds
    Flow RateAbout 30 L/h, low flow-dependence
    Shaft Lengthstandard 175 mm, and up to 220 mm in length (mA-Version)
    Connection2-pole terminal or M12 male
    MaterialPVC-U and semipermeable membrane
    Scope of Supplysensor, membrane cap, electrolyte
    Power Supply12~30V DC
    Signal Output4~20mA
    Application

    Drinking water,fresh water, process water.

    The water must not contain any surfactants

    pH-value must be constant.


    Item NumberModel

    Measuring range

    (ppm)

    Resolution

    (ppm)

    Output signalPower supply
    3326225CL4.2H-M0c0.005-2.0000.001Modbus RTU

    9-30V DC

    20-56mA

    3326226CL4.2N-M0c0.05-20.000.01
    3326227CL4.2L-M0c0.5-200.00.1

    3326240CL4.2MA0.50.01-0.500.014-20 mA

    12-30V DC

    RL: 50-900 Ω

    3326241CL4.2MA20.01- 2.000.01
    3326242CL4.2MA50.01-5.000.01
    3326243CL4.2MA100.01-10.000.01
    3326244CL4.2MA200.01- 20.000.01
    3326245CL4.2MA-1000.1-1000.1
    3326246CL4.2MA-2000.1-2000.1
    3326250CL4.2MA0.5-M120.01-0.500.014-20mA

    12-30V DC

    RL: 50-900 Ω

    3326251CL4.2MA2-M120.01-2.000.01
    3326252CL4.2MA5-M120.01-5.000.01
    3326253CL4.2MA10-M120.01-10.000.01
    3326254CL4.2MA20-M120.01-20.000.01
    3326255CL4.2MA-100-M120.1-1000.1
    3326256CL4.2MA-200-M120.1-2000.1

    Chlorine sensor with membrane-covered, amperometric 2-electrode system. For the measurement of free inorganic chlorine at constant pH.

    Areas of application: Fresh water free of surfactants and with constant pH
    Scope of supply: CL4.2: sensor, membrane cap, electrolyte

    Product description:

    1. Measurand(s) : NaClO (sodium hypochlorite), Ca(ClO)2 (calcium hypochlorite), Cl2 (chlorine gas), chlorine
    generated by membrane-electrolysis
    2. Calibration: at the controller, via analytical chlorine determination by DPD-1 method
    3. Interferences : ClO2 is being registered with factor 9 of its measured value; O3 is registered; with membrane-less chlorine electrolysis interferences may occur
    4. pH range: 6~8
    5. Pressure range: 0~1 bar, no pressure surges or fluctuations
    6. Temperature range: 0~ 45℃ (no ice crystals in measurement water)
    7. Integrated automatic temperature compensation
    8. Response time: T90 ca. 30 seconds
    9. Flow rate: about 30 l/h, low flow-dependence
    10. Shaft length: standard 175 mm, and up to 220 mm in length (mA-Version)
    11. Connection: for mA-version 2-pole terminal, M12 male or Modbus RTU with M12 male
    12. Material: PVC-U and semipermeable membrane