Sign In | Join Free | My himfr.com
Home > Chlorine Analyzer >

4 - 20MA Or RS485 Residual Chlorine Sensor CS4 With Flow Cell For Sewage Water Treatment

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 4 - 20MA Or RS485 Residual Chlorine Sensor CS4 With Flow Cell For Sewage Water Treatment from wholesalers
     
    Buy cheap 4 - 20MA Or RS485 Residual Chlorine Sensor CS4 With Flow Cell For Sewage Water Treatment from wholesalers
    • Buy cheap 4 - 20MA Or RS485 Residual Chlorine Sensor CS4 With Flow Cell For Sewage Water Treatment from wholesalers
    • Buy cheap 4 - 20MA Or RS485 Residual Chlorine Sensor CS4 With Flow Cell For Sewage Water Treatment from wholesalers
    • Buy cheap 4 - 20MA Or RS485 Residual Chlorine Sensor CS4 With Flow Cell For Sewage Water Treatment from wholesalers
    • Buy cheap 4 - 20MA Or RS485 Residual Chlorine Sensor CS4 With Flow Cell For Sewage Water Treatment from wholesalers
    • Buy cheap 4 - 20MA Or RS485 Residual Chlorine Sensor CS4 With Flow Cell For Sewage Water Treatment from wholesalers
    • Buy cheap 4 - 20MA Or RS485 Residual Chlorine Sensor CS4 With Flow Cell For Sewage Water Treatment from wholesalers
    • Buy cheap 4 - 20MA Or RS485 Residual Chlorine Sensor CS4 With Flow Cell For Sewage Water Treatment from wholesalers

    4 - 20MA Or RS485 Residual Chlorine Sensor CS4 With Flow Cell For Sewage Water Treatment

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : CS4
    Certification : CE
    Price : Negotiable
    • Product Details
    • Company Profile

    4 - 20MA Or RS485 Residual Chlorine Sensor CS4 With Flow Cell For Sewage Water Treatment

    4-20MA Or RS485 Residual Chlorine Sensor CS4 With Flow Cell For Sewage Water Treatment


    The film-coated online residual chlorine sensor is a sensor used to monitor the concentration of residual chlorine in water. It is usually used in water treatment, swimming pool monitoring, drinking water quality control and other fields.

    The principle of film covering method: film covering method sensors use special thin film materials, which react with residual chlorine and generate electrical signals. This principle can realize the detection of residual chlorine with high sensitivity.
    High sensitivity: film-coated sensors usually have high sensitivity and can detect very low concentrations of residual chlorine, which is very important for water quality monitoring and treatment.
    Real-time monitoring: This sensor can monitor the concentration of residual chlorine in water in real time, discover and deal with water quality problems in time, and help ensure the safety and stability of water quality.
    Digital Output: Many film-coated sensors have a digital output that can transmit data directly to a monitoring system or computer for easy data logging and analysis.
    Can run online: The sensor can run online for a long time without frequent maintenance, reducing the workload of operators.
    High stability: This type of sensor usually has high stability and long-term reliability, and can work under various environmental conditions.


    Advantage:
    Fast Response: Film-coated sensors are usually able to quickly respond to changes in residual chlorine concentration in a short period of time, helping to take timely measures to maintain water quality.
    Low Maintenance Costs: Sensors are relatively low maintenance because they do not require frequent replacement of sensing elements or consumables.
    Long Life: These sensors typically have a long life, lasting for many years without frequent replacement.
    High precision: film-coated sensors usually have high precision and can provide accurate measurement results of residual chlorine concentration.
    Automation Integration: They can be easily integrated into automated water treatment systems for automated water quality monitoring and regulation.


    Specifications

    IndicatorFree chlorine
    pH Range4-9pH
    Pressure Range0~3.0 bar, no pressure surges or fluctuations
    Temperature Range0~45℃
    Temp CompensationIntegrated automatic temperature compensation
    Response TimeT90 2mins
    Flow RateAbout 30 L/h, low flow-dependence
    Shaft LengthDiameter is 25mm standard 175 mm, and up to 220 mm in length (mA-Version)
    Connection2-pole terminal or M12 male
    MaterialPVC-U, PEEK, stainless steel 1.4571, microporous hydrophilic membrane
    Scope of SupplySensor, membrane cap, electrolyte
    Signal Output4~20mA/Modbus RTU(Optinal)
    Application

    Sewage, water treatment, It is suitable for measuring free inorganic chlorine and can also be used in seawater.


    Item numberModel

    Measuring range

    (ppm)

    Resolution(ppm)

    Output signalPower supply
    3426360CS4H-M0c0.005-2.0000.001Modbus RTU

    9-30V DC

    20-56mA

    3426361CS4N-M0c0.05-20.000.01
    3426362CS4L-M0c0.5-200.00.1

    3426303CS4MA20.01-2.000.014-20mA

    12-30V DC

    RL:50Ω-900Ω

    3426304CS4MA50.01-5.000.01
    3426305CS4MA100.01-10.000.01
    3426306CS4MA200.01-20.000.01
    3426307CS4MA2000.5-200.00.1

    3426313CS4MA2-M120.01-2.000.014-20mA

    12-30V DC

    RL:50Ω-900Ω

    3426314CS4MA5-M120.01-5.000.01
    3426315CS4MA10-M120.01-10.000.01
    3426316CS4MA20-M120.01-20.000.01
    3426317CS4MA200-M120.5-200.00.1

    Chlorine sensor with membrane-covered, amperometric 3-electrode system. For the measurement of free chlorine on the basis of iso-cyanuric acid, also in seawater.
    Areas of application: Fresh water and seawater; Surfactants are tolerated in part; a special electrolyte is used for seawater.
    Scope of supply:

    CC1: sensor, membrane cap, electrolyte for use in fresh water use

    Product description:

    1.Measurand(s): NaClO (sodium hypochlorite), Ca(OCl)2 (calcium hypochlo- rite), Cl2 (chlorine gas), electrolytically generated chlorine
    2.Calibration: at the controller, via analytical chlorine determination by DPD-1 method
    3.Interferences: 75 % of ClO2-concentration, 80 % of O3–concentration, combined chlorine may increase the
    measuring value
    4.pH range: 4~9
    5.Pressure range: 0~3.0 bar, no pressure surges and/or fluctuations
    6.Temperature range: 0~45 ℃
    7.Integrated automatic temperature compensation
    8.Response time: T90 about 2 min.

    9.Flow rate: about 30 l/h, low flow-dependence
    10.Shaft length: standard 175 mm, and up to 220 mm in length (mA-Version)
    11.Connection: for mA-version 2-pole terminal, M12 male or Modbus RTU with M12 male